Maximizing sensitivity of the psychomotor vigilance test (PVT) to sleep loss.

نویسندگان

  • Mathias Basner
  • David F Dinges
چکیده

STUDY OBJECTIVES The psychomotor vigilance test (PVT) is among the most widely used measures of behavioral alertness, but there is large variation among published studies in PVT performance outcomes and test durations. To promote standardization of the PVT and increase its sensitivity and specificity to sleep loss, we determined PVT metrics and task durations that optimally discriminated sleep deprived subjects from alert subjects. DESIGN Repeated-measures experiments involving 10-min PVT assessments every 2 h across both acute total sleep deprivation (TSD) and 5 days of chronic partial sleep deprivation (PSD). SETTING Controlled laboratory environment. PARTICIPANTS 74 healthy subjects (34 female), aged 22-45 years. INTERVENTIONS TSD experiment involving 33 h awake (N = 31 subjects) and a PSD experiment involving 5 nights of 4 h time in bed (N = 43 subjects). MEASUREMENTS AND RESULTS In a paired t-test paradigm and for both TSD and PSD, effect sizes of 10 different PVT performance outcomes were calculated. Effect sizes were high for both TSD (1.59-1.94) and PSD (0.88-1.21) for PVT metrics related to lapses and to measures of psychomotor speed, i.e., mean 1/RT (response time) and mean slowest 10% 1/RT. In contrast, PVT mean and median RT outcomes scored low to moderate effect sizes influenced by extreme values. Analyses facilitating only portions of the full 10-min PVT indicated that for some outcomes, high effect sizes could be achieved with PVT durations considerably shorter than 10 min, although metrics involving lapses seemed to profit from longer test durations in TSD. CONCLUSIONS Due to their superior conceptual and statistical properties and high sensitivity to sleep deprivation, metrics involving response speed and lapses should be considered primary outcomes for the 10-min PVT. In contrast, PVT mean and median metrics, which are among the most widely used outcomes, should be avoided as primary measures of alertness. Our analyses also suggest that some shorter-duration PVT versions may be sensitive to sleep loss, depending on the outcome variable selected, although this will need to be confirmed in comparative analyses of separate duration versions of the PVT. Using both sensitive PVT metrics and optimal test durations maximizes the sensitivity of the PVT to sleep loss and therefore potentially decreases the sample size needed to detect the same neurobehavioral deficit. We propose criteria to better standardize the 10-min PVT and facilitate between-study comparisons and meta-analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The sensitivity of a palm-based psychomotor vigilance task to severe sleep loss.

In this study, we evaluated the sensitivity of a 5-min personal digital assistant-psychomotor vigilance test (PDA-PVT) to severe sleep loss. Twenty-one participants completed a 10-min PVT-192 and a 5-min PDA-PVT at two hourly intervals during 62 h of sustained wakefulness. For both tasks, response speed and number of lapses (RTs > 500) per minute significantly increased with increasing hours of...

متن کامل

Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task.

INTRODUCTION In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min version of the psychomotor vigilance task (PVT) specifically designed for use on personal digital assistants (PDA), to 28 h of sustained wakefulness. METHODS There were 15...

متن کامل

Validity and Sensitivity of a Brief Psychomotor Vigilance Test (PVT-B) to Total and Partial Sleep Deprivation.

The Psychomotor Vigilance Test (PVT) objectively assesses fatigue-related changes in alertness associated with sleep loss, extended wakefulness, circadian misalignment, and time on task. The standard 10-min PVT is often considered impractical in applied contexts. To address this limitation, we developed a modified brief 3-min version of the PVT (PVT-B). The PVT-B was validated in controlled lab...

متن کامل

SHORT COMMUNICATION Fatigue Assessment in the Field: Validation of a Hand-Held Electronic Psychomotor Vigilance Task

LAMOND N, DAWSON D, ROACH GD. Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task. Aviat Space Environ Med 2005; 76:486–9. Introduction: In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min vers...

متن کامل

Tenth International Conference on Managing Fatigue: Abstract for Review Psychomotor Vigilance Task Evaluation for Touchscreen Devices

The Psychomotor Vigilance Task (PVT) is considered the gold standard fatigue detection device and is used frequently in fatigue research. With the rapid development of new technologies it is essential to develop PVT available on different platforms such as touchscreen devices. The big advantage of such PVT is that it can be implemented on small devices and can be easily used in field studies. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sleep

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2011