A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection

نویسندگان

  • Yanyan Xia
  • Han Shen
  • Yefei Zhu
  • Hongpan Xu
  • Zhiyang Li
  • Jin Si
چکیده

Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automated clinical chemistry analyzers. However, no studies have reported sufficient data on analytical performance of this method when using 3 monoclonal antibodies for GP73 measurement. The experimental conditions were firstly optimized and range of linearity, diagnostic potential, clinical relevance were compared with the LTIA based on polyclonal antibodies and ELISA. Dilution tests for the LTIA using 3 monoclonal antibodies produced a calibration curve from 10 to 350 ng/mL while the polyclonal antibodies produced the curve from 20 to 320 ng/mL. The detection limit was achieved at 1.82 ng/mL concentration. Within-run CV was obtained in the range of 1.5-2.9% and ROC curves indicated sensitivity and specificity of the LTIA based on 3 monoclonal antibodies were 96.7% and 93.3%, respectively, higher than for the polyclonal antibodies (94.6% and 72.4%) and ELISA (70.0% and 83.3%). Therefore, the LTIA assay based on 3 monoclonal antibodies is thus applicable in quantification of GP73 concentration in automated biochemistry analyzers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilization of turbidimetric immunoassay by covalent coupling of antibody to latex particles.

Turbidimetric immunoassay is commonly used to quantify serum proteins. Latex-particle enhancement of this type of assay has been primarily associated with increasing assay sensitivity. However, covalent coupling of an antibody to a latex particle can offer other advantages that are also pertinent in measurement of high concentrations of analytes. By using a common antibody with IgG as a model a...

متن کامل

Particle-enhanced turbidimetric immunoassay of sex-hormone-binding globulin in serum.

A particle-enhanced turbidimetric immunoassay (PETIA) for human sex-hormone-binding globulin (SHBG) is described. The method involves use of antibody covalently coupled to latex particles and is almost fully automated, with sample processing being complete in less than 20 min. The working reagents are stable for at least three months, and full calibration of the assay each day is not essential....

متن کامل

On-site determination of microalbuminuria based on Particle- Enhanced Turbidimetric-Inhibition Immunoassay (PETINIA) by portable fiber-optic spectrometer

A homemade fiber-optic spectrometer has been fabricated for portable and on-site determination of microalbuminuria. The principle of the method was based on particle-enhanced turbidimetric-inhibition immunoassay (PETINIA), which was not affected by the hook effect phenomenon. This method was linear from 0 to 150 mg L (r = 0.987), with a detection limit of 3.01 mg L (S/N = 3). The intra-assay co...

متن کامل

Evaluation of an automated assay based on monoclonal anti-human serum amyloid A (SAA) antibodies for measurement of canine, feline, and equine SAA.

Major acute phase proteins (APPs) have proven diagnostically useful in dogs, cats and horses with routine use facilitated by commercially available automated heterologous assays. An automated assay applicable across all three species would highly facilitate further dissemination of routine use, and the aim of this study was to validate an automated latex agglutination turbidimetric immunoassay ...

متن کامل

Particle-enhanced turbidimetric inhibition immunoassay for theophylline evaluated with the Du Pont aca.

We evaluated the Du Pont Particle-Enhanced Turbidimetric Inhibition Immunoassay (PETINIA) for theophylline. The imprecision (CV) of the assay was less than 4.7% between-run and less than 3.6% within-run for theophylline concentrations between 5 and 30 mg/L. Standard curves for the assay were linear for theophylline concentrations from 0 to 46 mg/L and were stable throughout the study (i.e., for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017