X-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f ) for copper using synchrotron radiation
نویسندگان
چکیده
We reconsider the long-standing problem of accurate measurement of atomic form factors for fundamental and applied problems. We discuss the X-ray extended-range technique for accurate measurement of the mass attenuation coefficient and the imaginary component of the atomic form factor. Novelties of this approach include the use of a synchrotron with detector normalisation, the direct calibration of dominant systematics using multiple thicknesses, and measurement over wide energy ranges with a resulting improvement of accuracies by an order of magnitude. This new technique achieves accuracies of 0.27– 0.5% and reproducibility of 0.02% for attenuation of copper from 8.84 to 20 keV, compared to accuracies of 10% using atomic vapours. This precision challenges available theoretical calculations. Discrepancies of 10% between current theory and experiments can now be addressed. 2001 Elsevier Science B.V. All rights reserved. PACS: 78.20.Ci; 32.80.Cy; 78.70.Dm; 78.20.Bh
منابع مشابه
Investigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray
Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...
متن کاملMeasurement of the x-ray mass attenuation coefficient and the imaginary part of the form factor of silicon using synchrotron radiation
We used the x-ray extended-range technique to measure the x-ray mass attenuation coefficients of silicon with an accuracy between 0.27% and 0.5% in the 5 keV220 keV energy range. Subtraction of the x-ray scattering contribution enabled us to derive the corresponding x-ray photoelectric absorption coefficients and determine the absolute value of the imaginary part of the atomic form factor of si...
متن کاملMeasurement of the x-ray mass attenuation coefficient of copper using 8.85–20 keV synchrotron radiation
This work presents the x-ray extended range technique for measuring x-ray mass attenuation coefficients. This technique includes the use of multiple foil attenuators at each energy investigated, allowing independent tests of detector linearity and of the harmonic contributions to the monochromated synchrotron beam. Measurements over a wide energy range allow the uncertainty of local foil thickn...
متن کاملUnfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملA Review of the Applications of Synchrotron Radiation in Archaeological Sciences
The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -