Discharge rate of sternohyoid motor units activated with surface EMG feedback.

نویسندگان

  • Dario Farina
  • Deborah Falla
چکیده

We analyzed individual motor units of the sternohyoid muscle with the aim of characterizing their minimum and maximum discharge rates and their variability in discharge during voluntary contractions. Surface EMG signals were recorded with an array of eight electrodes from the sternohyoid muscle of seven healthy men (age: 30.2+/-3.5 yr). The multichannel surface EMG signals were displayed as feedback for the subjects who identified and modulated the activity of one target motor unit in 30-s contractions during which the discharge rate was increased from minimum to maximum (ramp contraction), sustained at maximum level (sustained), or increased in brief bursts (burst). During the ramp contractions, the minimum average discharge rate over epochs of 1 s was 11.6+/-1.5 pulses per second (pps) and the maximum 57.0+/-5.7 pps (P<0.001). During the sustained contractions, the motor unit discharge rate decreased from 65.5+/-8.4 pps at the beginning to 52.9+/-7.6 pps at the end of the contraction (P<0.05). The coefficient of variation for the interspike interval during the sustained contractions was 40.2+/-9.8% and a large percentage of discharges had instantaneous rates>50 pps (52.2+/-12.5%) and>100 pps (8.0+/-1.2%), with peak values>150 pps. During the burst contractions, the instantaneous discharge rate reached average maximum values of 97.6+/-36.8 pps. The observed discharge rates and their variability are higher than those reported for limb muscles, which may be due to large synaptic input and noise received by these motor neurons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Progressive FastICA Peel-Off and Convolution Kernel Compensation Demonstrate High Agreement for High Density Surface EMG Decomposition

Decomposition of electromyograms (EMG) is a key approach to investigating motor unit plasticity. Various signal processing techniques have been developed for high density surface EMG decomposition, among which the convolution kernel compensation (CKC) has achieved high decomposition yield with extensive validation. Very recently, a progressive FastICA peel-off (PFP) framework has also been deve...

متن کامل

Regional differences in length change and electromyographic heterogeneity in sternohyoid muscle during infant mammalian swallowing.

A complex sling of muscles moves and stabilizes the hyoid bone during many mammalian behaviors. One muscle in this sling, the sternohyoid, is recruited during food acquisition, processing, and swallowing, and also during nonfeeding behaviors. We used synchronous sonomicrometry and electromyography to investigate regional (intramuscular) changes in length and electromyographic (EMG) activity of ...

متن کامل

Conduction velocity of low-threshold motor units during ischemic contractions performed with surface EMG feedback.

The aim of this study was to analyze the effect of ischemia on low-threshold motor unit conduction velocity. Nine subjects were trained to isolate the activity of a single motor unit (target motor unit) in the abductor pollicis brevis muscle with feedback on surface EMG signals recorded with a 16-electrode linear array. After training, the subjects activated the target motor unit at approximate...

متن کامل

Amplitude cancellation reduces the size of motor unit potentials averaged from the surface EMG.

The purpose of the study was to evaluate the influence of selected physiological parameters on amplitude cancellation in the simulated surface electromyogram (EMG) and the consequences for spike-triggered averages of motor unit potentials derived from the interference and rectified EMG signals. The surface EMG was simulated from prescribed recruitment and rate coding characteristics of a motor ...

متن کامل

Discharge properties of motor units of the abductor hallucis muscle during cramp contractions.

We analyzed individual motor units during electrically elicited cramp contractions with the aim of characterizing the variability and degree of common oscillations in their discharges. Intramuscular and surface electromyographic (EMG) signals were detected from the abductor hallucis muscle of 11 healthy subjects (age 27.0+/-3.7 yr) during electrically elicited cramps. In all, 48 motor units wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 101 2  شماره 

صفحات  -

تاریخ انتشار 2009