Patient specific heart models from high resolution CT

نویسندگان

  • Chandrajit L. Bajaj
  • Samrat Goswami
  • Zeyun Yu
  • Yongjie Zhang
  • Yuri Bazilevs
  • Thomas J. R. Hughes
چکیده

Computer Tomography (CT) and in particular super fast, 64 and 256 detector CT has rapidly advanced over recent years, such that high resolution cardiac imaging has become a reality. In this paper, we provide a solution to the problem of automatically constructing three dimensional (3D) finite-element mesh models (FEM) of the human heart directly from high resolution CT. Our overall computational pipeline from 3D imaging to FEM models has five main steps, namely, (i) discrete voxel segmentation of the CT (ii) discrete topological noise filtering to remove non-regularized, and small geometric measure artifacts (iii) a reconstruction of the inner and outer surface boundaries of the human heart and its chambers (iv) computation of the medial axis of the heart boundaries and a volumetric decomposition of the heart into tubular, planar and chunky regions, (v) a flexible match and fit of each of the decomposed volumetric regions using segmented anatomical volumetric templates obtained from a 3D model heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatially Realistic Human Heart Finite Element Models from Medical Imaging

Computer Tomography (CT) and in particular super fast, 64 and 256 detector CT has rapidly advanced over recent years, such that excellent spatial resolution cardiac imaging, with highly reduced motion artifacts, has become a reality. In this paper, we introduce and apply our comprehensive framework to construct spatially realistic three dimensional (3D) finiteelement and boundary element mesh m...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System

Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray  examinations and it contributes 34% of the resultant collective dose worldwide. Children are more  sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be  carried out periodically on the CT scanners. The aim of this research was to estimate the effective  ...

متن کامل

Effect of Heart Rate on CT Angiography Using the Enhanced Cardiac Model of the 4D NCAT

We investigate the effect of heart rate on the quality and artifact generation in coronary artery images obtained using multi-slice computed tomography (MSCT) with the purpose of finding the optimal time resolution for data acquisition. To perform the study, we used the 4D NCAT phantom, a computer model of the normal human anatomy and cardiac and respiratory motions developed in our laboratory....

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006