Minimum current requirement for confirming the localization of an epiradicular catheter placement

نویسندگان

  • Ji Seon Jeong
  • Jae Chol Shim
  • Jae Hang Shim
  • Dong Won Kim
  • Min Serk Kang
چکیده

BACKGROUND Based on the necessity to confirm the epiradicular catheter misplacement, epiradicular threshold current for the confirmation of catheter tip localization is required. METHODS Thirty-four adult patients with low extremity radiating pain were to receive epiradicular catheterization at the lumbosacral level. The epidural space was accessed percutaneously in cranial to caudal direction. A metal coil-reinforced epidural catheter was inserted and advanced caudolaterally toward the target neural foramen until the catheter tip was located below the bisection of pedicle. The electrical stimulation was performed after catheter placement in epidural and epiradicular space. Using the constant current nerve stimulator, the stimulating current was increased from 0 to 5 mA (pulse width of 0.3 ms; frequency of 2 Hz) until adequate motor contraction was evident. The threshold current for motor response with epidural space (EDmA) and epiradicular space (ERmA) placement were recorded upon electrical stimulation. In addition, the threshold charge for motor response with epidural (EDnC) and epiradicular (ERnC) placement were recorded. RESULTS Of 34 catheters intentionally placed in the epiradicular space, ERmA was 0.53 ± 0.48 mA. The ERnC was significantly lower than EDnC (P < 0.05). The EDmA and ERmA were below 1 mA in 3 patients and above 1 mA in 4 patients, respectively. CONCLUSIONS We conclude that, threshold current for motor response seems to be lower for epiradicular compared with epidural placement, although we were not able to directly investigate the epidural threshold current. The threshold current of epiradicular space overlap that in the epidural space.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strategic placement of epidural catheter

Corresponding author: Jae-Hang Shim, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Hanyang University Hospital, 249-1, Gyomun-dong, Guri 471-701, Korea. Tel: 82-31-560-2390, Fax: 82-31-563-1731, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by...

متن کامل

On improving APIT algorithm for better localization in WSN

In Wireless Sensor Networks (WSNs), localization algorithms could be range-based or range-free. The Approximate Point in Triangle (APIT) is a range-free approach. We propose modification of the APIT algorithm and refer as modified-APIT. We select suitable triangles with appropriate distance between anchors to reduce PIT test errors (edge effect and non-uniform placement of neighbours) in APIT a...

متن کامل

A prospective comparative study of two indirect methods for confirming the localization of an epidural catheter for postoperative analgesia.

We prospectively evaluated, in randomized order, 2 indirect methods of confirming the localization of an epidural catheter for postoperative analgesia in 218 surgical patients: epidural stimulation test (EST) and epidural pressure waveform analysis (EPWA). The epidural space was localized by using a loss of resistance technique. All catheters were inserted 5 cm into the epidural space and prime...

متن کامل

Optimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping

This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...

متن کامل

Conservative management of superior vena cava injury due to hemodialysis catheter placement: A case report and literature review

We reported the case of a 78-year old woman with the inadvertent superior vena cava injury resulting from hemodialysis catheter placement. The catheter was placed through the left internal jugular vein. Hemodynamics were stable. The initial chest film illustrated an extraluminal catheter and mediastinal widening. The patient did not have hemothorax. Computed tomography venography also confirmed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 63  شماره 

صفحات  -

تاریخ انتشار 2012