Factors associated with false‐negative cardiovascular magnetic resonance perfusion studies: A Clinical evaluation of magnetic resonance imaging in coronary artery disease (CE‐MARC) substudy
نویسندگان
چکیده
PURPOSE To examine factors associated with false-negative cardiovascular magnetic resonance (MR) perfusion studies within the large prospective Clinical Evaluation of MR imaging in Coronary artery disease (CE-MARC) study population. Myocardial perfusion MR has excellent diagnostic accuracy to detect coronary heart disease (CHD). However, causes of false-negative MR perfusion studies are not well understood. MATERIALS AND METHODS CE-MARC prospectively recruited patients with suspected CHD and mandated MR, myocardial perfusion scintigraphy, and invasive angiography. This subanalysis identified all patients with significant coronary stenosis by quantitative coronary angiography (QCA) and MR perfusion (1.5T, T1 -weighted gradient echo), using the original blinded image read. We explored patient and imaging characteristics related to false-negative or true-positive MR perfusion results, with reference to QCA. Multivariate regression analysis assessed the likelihood of false-negative MR perfusion according to four characteristics: poor image quality, triple-vessel disease, inadequate hemodynamic response to adenosine, and Duke jeopardy score (angiographic myocardium-at-risk score). RESULTS In all, 265 (39%) patients had significant angiographic disease (mean age 62, 79% male). Thirty-five (5%) had false-negative and 230 (34%) true-positive MR perfusion. Poor MR perfusion image quality, triple-vessel disease, and inadequate hemodynamic response were similar between false-negative and true-positive groups (odds ratio, OR [95% confidence interval, CI]: 4.1 (0.82-21.0), P = 0.09; 1.2 (0.20-7.1), P = 0.85, and 1.6 (0.65-3.8), P = 0.31, respectively). Mean Duke jeopardy score was significantly lower in the false-negative group (2.6 ± 1.7 vs. 5.4 ± 3.0, OR 0.34 (0.21-0.53), P < 0.0001). CONCLUSION False-negative cardiovascular MR perfusion studies are uncommon, and more common in patients with lower angiographic myocardium-at-risk. In CE-MARC, poor image quality, triple-vessel disease, and inadequate hemodynamic response were not significantly associated with false-negative MR perfusion.
منابع مشابه
Associated factors for a false negative cardiovascular magnetic resonance perfusion study: a CE-MARC substudy
Background Diagnosis of coronary ischemia by perfusion CMR has high sensitivity and specificity when using X-ray coronary angiography as the reference standard. A variety of possible reasons have been given for false negative perfusion CMR studies, such as suboptimal image quality, technical reasons, or the potential discrepancy between angiographic stenosis and detectable myocardial hypoperfus...
متن کاملRelationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction
Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...
متن کاملA comparison of cardiovascular magnetic resonance and single photon emission computed tomography (SPECT) perfusion imaging in left main stem or equivalent coronary artery disease: a CE-MARC substudy
BACKGROUND Assessment of left main stem (LMS) stenosis has prognostic and therapeutic implications. Data on assessment of LMS disease by cardiovascular magnetic resonance (CMR) and single photon emission computed tomography (SPECT) are limited. CE-MARC is the largest prospective comparison of CMR and SPECT against quantitative invasive coronary angiography (QCA) for detection of coronary artery...
متن کاملThe Essence of STRATEGY Is Choosing What Not to Do.
Clinicians must evaluate on a daily basis patients with symptoms of possible coronary artery disease (CAD). Decades of progress in various technologies used for cardiovascular imaging have produced a wide array of choices, and consequently selecting the best test for a given patient has become increasingly complex. Anatomic techniques to evaluate for CAD include invasive coronary angiography (I...
متن کاملCardiovascular magnetic resonance stress perfusion compared to single-photon emission computed tomography (SPECT) in patients with left main stem disease: a CE-MARC substudy
We compared detection rates for cardiovascular magnetic resonance (CMR) perfusion and single photon emission tomography (SPECT) in the subset of patients from the CE-MARC study with significant left main stem (LMS) disease. Detection rates for LMS disease by CMR perfusion were higher than for SPECT, and CMR identified a classical LMS pattern with higher frequency. Visual perfusion defects occur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 43 شماره
صفحات -
تاریخ انتشار 2016