Myocardial T2* mapping: influence of noise on accuracy and precision
نویسندگان
چکیده
BACKGROUND Pixel-wise, parametric T2* mapping is emerging as a means of automatic measurement of iron content in tissues. It enables quick, intuitive interpretation and provides the potential benefit of spatial context between tissues. However, pixel-wise mapping uses much lower SNR data to estimate T2* when compared to region-based mapping thereby decreasing both its accuracy and precision. In this study, the effects that noise has on the precision and accuracy of pixel-wise T2* mapping were investigated and techniques to mitigate those effects are proposed. METHODS To study precision across T2* mapping techniques, a pipeline to estimate the pixel-wise standard deviation (SD) of the T2* based on the fit residuals is proposed. For validation, a Monte-Carlo analysis was performed in which T2* phantoms were scanned N = 64 times, the true SD was measured and compared to the estimated SD. To improve accuracy and precision, the automatic truncation method for mitigating noise bias was extended to pixel-wise fitting by using an SNR scaled image reconstruction and truncating low SNR measurements. Finally, the precision and accuracy of non-linear regression with and without automatic truncation, were investigated using Monte-Carlo simulations. RESULTS Measured and estimated SD's were >99.9% correlated for non-linear regression with and without truncation. Non-linear regression with automatic truncation was shown to be the best mapping technique for improving accuracy and precision in low T2* and low SNR measurements. CONCLUSIONS A method for applying an automatic truncation method to pixel-wise T2* mapping that reduces T2* overestimation due to noise bias was proposed. A formulation for estimating pixel-wise standard deviation (SD) maps for T2* that can serve as a quality map for interpreting images and for comparison of imaging protocols was also proposed and validated.
منابع مشابه
Precision and reproducibility of T2 quantifications in myocardial T2 mapping: impact of the number of echoes and reconstruction model
Background Quantitative myocardial T2 is a promising technique to assess myocardial inflammation and edema (1). Recent implementations have utilized T2-prepared (T2prep) SSFP sequences to acquire a multiple T2 weighted images at different echo times, and generate T2 maps based on a 2-parameter (2P-fit) model of T2 decay (2,3). Recently, a 3-parameter fitting (3P-fit) model was found superior to...
متن کاملAccuracy and precision of Cartilage T2-relaxation time Quantification: Impact of the Fit method
Introduction: T2 relaxation time quantification has high potential for the diagnostic work up of cartilage, especially in early osteoarthritis. T2 calculation relies on fitting data acquired at different echo times (TE) from multi-echo sequences (MES) to an exponential equation, which is assumed to reflect transverse magnetization decay. The low T2 times in articular cartilage (between 10 and 5...
متن کاملJoint myocardial T1 and T2 mapping using a combination of saturation recovery and T2 -preparation.
PURPOSE To develop a heart-rate independent breath-held joint T1 -T2 mapping sequence for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. METHODS A novel preparation scheme combining both a saturation pulse and T2 -preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2 -preparation is varied in each ...
متن کاملOn the selection of sampling points for myocardial T1 mapping.
PURPOSE To provide a method for the optimal selection of sampling points for myocardial T1 mapping, and to evaluate how this selection affects the precision. THEORY The Cramér-Rao lower bound on the variance of the unbiased estimator was derived for the sampling of the longitudinal magnetization curve, as a function of T1 , signal-to-noise ratio, and noise mean. The bound was then minimized n...
متن کاملReproducibility of slice-interleaved myocardial T2 mapping sequences
Background Myocardial T2 mapping sequence allows quantitative assessment of myocardial edema and inflammation. Commonly, a series of T2 weighted images with steadystate free-precession (SSFP) are acquired after T2 magnetization preparation (T2Prep) with different echo times. Conventionally, a single slice per breath-hold is acquired to image one single slice. Because inflammation/edema is often...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015