Cross-reactivity of designer drugs, including cathinone derivatives, in commercial enzyme-linked immunosorbent assays.

نویسندگان

  • Madeleine J Swortwood
  • W Lee Hearn
  • Anthony P DeCaprio
چکیده

Since the introduction of synthetic heroin, designer drugs have been increasing in prevalence in the United States drug market over the past few decades. Recently, 'legal highs' sold as 'bath salts' have become a household term for one such class of designer drugs. While a number of federal and state bans have been enacted, the abuse of these designer drugs still continues. Few assays have been developed for the comprehensive detection of such compounds, so it is important to investigate how they may or may not react in presumptive screens, i.e. pre-existing commercial immunoassays. In this experiment, 16 different ELISA reagents were evaluated to determine the cross-reactivity of 30 designer drugs, including 24 phenylethylamines (including 8 cathinone derivatives), 3 piperazines, and 3 tryptamines. Cross-reactivity towards most drugs was <4% in assays targeting amphetamine or methamphetamine. Compounds such as MDA, MDMA, ethylamphetamine, and α-methyltryptamine demonstrated cross-reactivities in the range of 30-250%, but data were consistent with both manufacturer's inserts and published literature. When tested against the Randox Mephedrone/Methcathinone kit, cathinone derivatives demonstrated cross-reactivity at concentrations as low as 150 ng/ml. Since this same reagent did not cross-react with other amphetamine-like compounds, it opens the possibility to screen post-mortem specimens without the interference of putrefactive amines. All other assays demonstrated essentially no cross-reactivity towards any of the analytes evaluated. Given these results, a great need exists for more broad-range screening techniques to be applied when analyzing biological specimens by immunoassays for drugs of abuse, specifically the more recent designer drugs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of designer drug cross-reactivity on five commercial immunoassay screening kits.

The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural s...

متن کامل

Enzyme-Linked Immunosorbent Assay of Progesterone in Serum Using Penicillinase as Label

An enzyme-linked immunosorbent assay (ELISA) for progesterone measurement in serum or plasma samples using penicillinase as label enzyme is reported. A C3 and C11 derivatives of progesterone were prepared and conjugated to bovin serum albumin (BSA). Polyclonal antibody against these two immunogens were prepared in New Zealand white rabbits. Purified Ig fractions of antibodies were immobilized o...

متن کامل

ENZYME-LINKED IMMUNOSORBENT ASSAY OF NEOPTERIN USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay for neopterin using penicillinase as marker enzyme is reported here by polyclonal antibodies against neopterin conjugated to bovine serum albumin which were raised in rabbits. Immunoglobulin fractions were purified and coated on wells of microtiter plates. A chain heterology was introduced in neopterin derivative and conjugated to penicillinase. The assa...

متن کامل

Production of monoclonal antibodies against recombinant nucleoprotein of avian influenza virus, serotype H9N2

Background: Avian influenza viruses (AIVs) including the subtype H9N2 cause considerable financial losses to poultry industries. Rapid and accurate diagnosis of avian influenza (AI) infection is important in control and eradication programs. OBJECTIVES: The aim of this study was to produce monoclonal antibodies (MAbs) specific for the nucleocapsid protein )NP (of AIV H9N2 subtype to improve dia...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Drug testing and analysis

دوره 6 7-8  شماره 

صفحات  -

تاریخ انتشار 2014