Feasibility and Reproducibility of Echo Planar Spectroscopic Imaging on the Quantification of Hepatic Fat
نویسندگان
چکیده
OBJECTIVES 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC). When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI) on the quantification of HFC in subject with various HFCs. METHODS Twenty two volunteers were examined in a 3T MR system. The acquisition time of proposed EPSI protocol was 18 seconds. The EPSI scans were repeated 8 times for each subject to test reproducibility. The peak of water and individual peaks of fat including methyl, methylene, and allylic peaks at 0.9, 1.3, and 2.0 ppm were fitted. Calculated amount of water and fat content were corrected for T2 relaxation. The total HFC was defined as the combination of individual peaks. Standard deviation (SD), coefficient of variance (COV) and fitting reliability of HFC quantified by LCModel were calculated. RESULTS Our results show that the SDs of total HFC for all subjects are less than 2.5%. Fitting reliability is mostly under 10% and positively correlates with COV. Subjects separated into three subgroups according to quantified total HFC show that improved fitting reliability and reproducibility can be achieved on subjects with higher total HFC. CONCLUSIONS We have demonstrated feasibility of the proposed EPSI protocols on the quantification of HFC over a whole slice of liver with scan time in a single breath hold.
منابع مشابه
Multi-Echo based Correlated Spectroscopic Imaging
Introduction – Despite the many advantages of Chemical Shift Imaging (CSI) [1] over ordinary single voxel spectroscopy, its onedimensional (1D) spectra are still limited by severe spectral overlap, which can complicate quantification of metabolites. Twodimensional Magnetic Resonance Spectroscopy (2D MRS) aims to alleviate the quantification problems due to spectral overlap by pushing resonances...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملQuantification of partial volume effects in planar imaging
Introduction: The limited resolution of the imaging system causes partial volume effects (PVEs). These results in spreading of image counts to the neighboring pixels. This phenomenon is called spill-out effect. This study aimed at quantifying PVEs using ImageJ. Methods:Technetium-99m solution of concentration of 74 kBq/ml was filled into spheres A, B<...
متن کامل[Fatty liver quantification with line scan echo planar spectroscopic imaging (LSEPSI)].
INTRODUCTION Although fatty infiltration of liver is a benign process that generally results from chronic alcohol uptake or obesity, such lifestyle factors may lead to chronic disease. Measuring the fat concentration in liver may therefore prove useful in assessing disease status. In this study, we report the usefulness of line scan echo planar spectroscopic imaging (LSEPSI) for this problem. ...
متن کاملSpectroscopic imaging using concentrically circular echo-planar trajectories in vivo.
An alternative to the standard echo-planar spectroscopic imaging technique is presented, spectroscopic imaging using concentrically circular echo-planar trajectories (SI-CONCEPT). In contrast to the conventional chemical shift imaging data, the sampled data from each set of concentric rings were regridded into Cartesian space. Usage of concentric k-space trajectories has the advantage of requir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014