Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

نویسندگان

  • Yee-Seo Kwon
  • Hee Namgoong
  • Jung-Hoon Kim
  • In Hee Cho
  • Myung Duk Kim
  • Tae Gwan Eom
  • Ki-Tae Koo
چکیده

PURPOSE The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). METHODS Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The P1-M1 teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. RESULTS No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. CONCLUSIONS The existence of microthreads was not a significant factor in mechanical and histological stability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twist removal of healed vs. nonhealed implants—a mechanical and histological study in mini pigs

PURPOSE The objective of this study was to evaluate the effect of removal torque (reverse torque) of titanium implants in peri-implant bone. METHODS The P1-M1 teeth were extracted bilaterally of 6 mini pigs (BR-1). Each animal received 6 titanium implants, three for each side of mandible. On the right side of mandible, 3 implants reminded 9 months (9M) under masticatory activity and on the le...

متن کامل

Removal torque values of titanium implants in the maxilla of miniature pigs.

The purpose of this study was to compare side-by-side two different titanium screw-type implants in the maxillae of miniature pigs. The test implants had a machined and acid-etched surface (Osseotite) whereas the control implants were sandblasted and acid-etched (SLA). After 4, 8, and 12 weeks of healing, removal torque testing was performed to evaluate the shear strength of the bone-implant in...

متن کامل

An Investigation of the Efficacy of Cuttlefish Bone Powder in the Removal of Reactive Blue 19 Dye from Aqueous Solutions: Equilibrium and Isotherm Studies

Introduction: Discharge of textile wastewater causes the reduction of sunlight penetration, interferes with the receiving waters ecology and damage the environment. The aim of this study was to determine the removal efficiency of reactive blue 19 dye from aqueous solutions by cuttlefish bone powder. Materials & Methods: This study was performed experimentally and in laboratory scale. In thi...

متن کامل

تحلیل بیومکانیکی پیچ و مخروط و آنالیز حساسیت شل شدن اباتمنت در ایمپلنت‌های دندانی

Background and Aims: Different mechanisms have been developed for connecting abutment to implant. One of the most popular mechanisms is Tapered Integrated Screw (TIS), which is a Tapered Interference Fit (TIF) with a screw integrated at the bottom of that. The aim of this study was to investigate the mechanism of TIS and effective factors in employing TIS during design and implementation proces...

متن کامل

Biological responses of anodized titanium implants under different current voltages.

The oxide layer of a titanium surface is very stable, and seems to result in excellent biocompatibility and successful osseointegration. The purpose of this study was to investigate the effects of high anodic oxidation voltages on the surface characteristics of titanium implants and the biologic response of rabbit tibiae. Bone tissue responses were evaluated by removal torque tests and histomor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2013