Comparison of bipolar and unipolar programmed electrical stimulation for the initiation of ventricular arrhythmias: significance of anodal excitation during bipolar stimulation.
نویسندگان
چکیده
To determine if anodal excitation during bipolar stimulation facilitates the initiation of sustained monomorphic ventricular tachycardia, nonsustained polymorphic ventricular tachycardia, or repetitive ventricular responses, both bipolar and cathodal unipolar programmed ventricular stimulation with one to three extrastimuli delivered during ventricular pacing at two rates from the right ventricular apex were performed in 28 patients evaluated for spontaneous sustained ventricular tachycardia or ventricular fibrillation (11 patients), nonsustained tachycardia (eight patients), or syncope (nine patients). In 25 patients a hexapolar pacing catheter was used to record local endocardial activation times adjacent to the cathode and anode and ventricular excitation during bipolar stimulation was defined as predominantly anodal, cathodal, or simultaneous at both anode and cathode. When bipolar and unipolar stimulation were compared there was no difference in the incidence of initiating sustained monomorphic ventricular tachycardia (57% vs 57%), nonsustained polymorphic ventricular tachycardia (14% vs 14%), or repetitive ventricular responses (21% vs 21%), although the response to bipolar vs unipolar stimulation was not concordant in every patient. Evidence of anodal excitation was observed in 11 (44%) patients but did not indicate increased risk of initiation of any ventricular arrhythmia, despite the fact that it was associated with shortening of the ventricular effective refractory period by 5.2 +/- 8.7 msec (p less than .05) during bipolar as opposed to unipolar stimulation. We conclude that unipolar and bipolar stimulation produce a similar incidence of initiation of arrhythmia, despite the frequent occurrence of anodal excitation during bipolar stimulation. Thus, the risk of initiation of nonspecific ventricular arrhythmias during programmed stimulation is unlikely to be reduced by the use of unipolar stimulation.
منابع مشابه
DIAGNOSTIC METHODS ELECTROPHYSIOLOGY Comparison of bipolar and unipolar programmed electrical stimulation for the initiation of ventricular arrhythmias: significance of anodal excitation during bipolar stimulation
To determine if anodal excitation during bipolar stimulation facilitates the initiation of sustained monomorphic ventricular tachycardia, nonsustained polymorphic ventricular tachycardia, or repetitive ventricular responses, both bipolar and cathodal unipolar programmed ventricular stimulation with one to three extrastimuli delivered during ventricular pacing at two rates from the right ventric...
متن کاملVulnerability of the mildly ischemic ventricle to cathodal, anodal, and bipolar stimulation.
We studied the difference between myocardial vulnerability to arrhythmias caused by cathodal, anodal, and bipolar stimulation in 29 dogs with partial right coronary artery occlusion. We used 2-msec duration stimuli of up to 8 mA to determine the ventricular vulnerable periods, their relationship to the refractory periods, and the fibrillation or multiple response thresholds for unipolar anodal ...
متن کاملProgrammed electrical stimulation of the heart in patients with life-threatening ventricular arrhythmias: what is the significance of induced arrhythmias and what is the correct stimulation protocol?
FEATURES Programmed electrical stimulation of the heart in patients with life-threatening ventricular arrhythmias: What is the significance of induced arrhythmias and what is the correct stimulation protocol? FOLLOWING ITS INTRODUCTION into the practice of cardiology in 1972,1 programmed electrical stimulation (PES) of the heart has developed from a technique used for diagnostic purposes into o...
متن کاملAnodal stimulation as a cause of pacemaker-induced ventricular fibrillation.
T he possibility of pacemaker-induced ventricular arrhythmias has been recognized since the beginning of widespread use of artificial pacemakers,*-I6 but the extent of the clinical risk of such arrhythmias has been questionable.17-2* The possibility of a dangerous arrhythmia being precipitated by a pacemaker stimulus falling during the vulnerable period of a preceding ventricular beat exists mo...
متن کاملThe ventricular excitability-interval relationship in early diastole in humans: the influence of the electrode configuration during bipolar stimulation.
The purpose of this study was to determine the relationship between ventricular excitability and the extrastimulus (S2) coupling interval in early diastole in humans. The influence of the electrode configuration during bipolar stimulation was examined. Ventricular strength-interval curves were constructed using an eight beat drive train at a cycle length of 600 msec, 2-msec decrements in the S2...