We report on the mechanical characterization and modeling of a non-prestretched dielectric elastomer diaphragm microactuator with ion-implanted electrodes under the influence of a distributed load (pressure). Thin PDMS membranes (30 μm thick, 2-3 mm diameter) were implanted on both side with gold ions by Filtered Cathodic Vacuum Arc and bonded on silicon chips with through-holes. A voltage applied between the implanted electrodes creates a compressive stress in the dielectric and causes the membrane to buckle and form a bump whose height depends on the mechanical properties of the electroactive compound, the voltage and the force applied on the membrane. Maximum unloaded displacements up to 7% of the membrane’s lateral dimensions were achieved, which was reduced to 3% when a distributed force of 1 kPa was applied on the membrane. The maximum mechanical work obtained by the actuators is in the range of 0.3 μJ. An analytical model was developped to calculate the displacement of the DEAs based on their mechanical and geometrical properties, voltage and applied force. The model shows very good agreement with the measurements and allows accurate performance prediction and dimensioning of such actuators.
منابع مشابه
Ion-implanted compliant and patternable electrodes for miniaturized dielectric elastomer actuators
This article presents metal ion implantation as an alternative technique to fabricate compliant electrodes for small-size dielectric elastomer actuators. When reducing the size of these actuators to below 1 cm, the ability to pattern the electrodes is added to the need for compliance. Metal ion implantation on Polydimethylsiloxane (PDMS) layers allows the creation of conductive and compliant el...
متن کاملMicrofabrication and characterization of an array of dielectric elastomer actuators generating uniaxial strain to stretch individual cells
Cells regulate their behavior in response to mechanical strains. Cell cultures to study mechanotransuction are typically cm2 in area, far too large to monitor single cell response. We have developed an array of dielectric elastomer microactuators as a tool to study mechanotransduction of individual cells. The array consists of 72 100 μm × 200 μm electroactive polymer actuators which expand unia...
متن کاملMultilayer Dielectric Elastomer Actuators with Ion Implanted Electrodes
We present the design, fabrication process and characterization of multilayer miniaturized polydimethylsiloxane (PDMS)-based dielectric elastomer diaphragm actuators. The conductive stretchable electrodes are obtained by lowenergy metal ion implantation. To increase force, decrease the required voltage, and avoid dielectric breakdown, we present here a technique to fabricate multilayer devices ...
متن کاملMetal Ion Implanted Compliant Electrodes in Dielectric Electroactive Polymer (EAP) Membranes
One of the key factors to obtain large displacements and high efficiency with dielectric electroactive polymer (DEAPs) actuators is to have compliant electrodes. Attempts to scale DEAPs down to the mm or micrometer range have encountered major difficulties, mostly due to the challenge of micropatterning sufficiently compliant electrodes. Simply evaporating or sputtering thin metallic films on e...
متن کاملAn array of 100μm×100μm dielectric elastomer actuators with 80% strain for tissue engineering applications
Biological cells modulate their behavior, express genes, proliferate or differentiate in response to mechanical strains ranging from 1% to 20%. There currently exists no technique to apply strain to many targeted individual cells in a larger culture in order to perform parallelized high throughput testing. Dielectric elastomer actuators (DEAs) are compliant devices capable of generating large p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008