Novel Thermal Resistance Network Analysis of Heat Sink with Embedded Heat Pipes

نویسنده

  • Jung-Chang Wang
چکیده

This article utilizes the experimental method to investigate the thermal performance of heat sinks with one and two pairs of embedded heat pipes. A heat sink with embedded heat pipes transfers the total heat capacity from the heat source to both the base plate and heat pipes, and then disperses heat into the surrounding air via the forced convection. The heat transference from base plate to fins can be conducted through the examined results of the heat sink with and without the function of heat pipes. The heat capacity from heat pipes to fins is equal to the total heat minus the heat from base plate to fins. Therefore, the heat carried by embedded heat pipes can be found using the thermal resistance analytical approach stated in this article. The results show that two and four heat pipes embedded in the base plate carry 36% and 48% of the total dissipated heat respectively; in addition, when the total heating power of the heat sink with two embedded heat pipes is 140W, the total thermal resistance reaches its minimum value of 0.27oC/W, while for the heat sink with four embedded heat pipes, when the total heating power is between 40W and 240W, the total thermal resistance is 0.24oC/W, meaning that the thermal performance is better than that of heat sink with two embedded heat pipes. © 2008 Jordan Journal of Mechanical and Industrial Engineering. All rights reserved

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation of Heat Transfer Enhancement in a Finned U-Shaped Heat Pipe of CPU Cooling System Using Different Fluids

This paper experimentally studies the heat absorption performance of a heat sink with vertical embedded heat pipes in the aluminum blade. The cooling system with embedded heat pipes distributes heat from the CPU to both the base plate and the heat pipes, and then transfer heat from fins to the Environment. The thermal resistance and heat transfer coefficient are evaluated for natural convection...

متن کامل

A numerical investigation of heat transfer and pressure drop in a novel cylindrical heat sink with helical minichannels

This study numerically investigated heat transfer and fluid flow characteristics in a novel cylindrical heat sink with helical minichannels for the laminar flow of fluid with temperature-dependent properties. A finite volume method was employed to obtain the solution of governing equations. The effects of helical angle, channel aspect ratio, and Reynolds number, which were regarded as main para...

متن کامل

Experimental Investigation on CuO/Water Nanofluid Effect on the Heat Transfer Rate of Heat Pipe Network

In this study, a new configuration of heat pipes as Heat Pipe Network is introduced. Here, the heat pipe network is designed, constructed and then has been under the performance assessment. This heat pipe network consists of 4 vertical heat pipes connected to evaporator collector from bottom and condenser collector from top. In order to investigate the effect of nanofluids on the thermal effici...

متن کامل

Determination of Thermal Resistance in Three-Dimensional Analysis of Micro-Channel Heat Sink with Non - Newtonian Fluids

Micro-Channel Heat Sink is a heat exchanger which is used to control the temperature of electronic devices with high heat flux. A comprehensive thermal model for the micro-channels should include three dimensional conduction analysis in the solid body together with three dimensional developing fluid flow as well as heat transfer analyses in the fluid section. This paper reports on a research ...

متن کامل

High Heat Flux Heat Pipes Embedded in Metal Core Printed Circuit Boards

As LED applications continue to expand beyond lighting and sensors, the power levels and heat dissipation requirements will also continue to increase. Thermal management is becoming a major design issue for highpower LED systems. The size and weight of conventional bulk metal heat sinks cannot satisfy shrinking packaging constraints. Active cooling methods, such as forced air cooling or even pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008