Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism.

نویسندگان

  • Eloísa Urrechaga
  • Luís Borque
  • Jesús F Escanero
چکیده

BACKGROUND New erythrocyte parameters are reported by the Sysmex XE 5000 analyzer. This instrument measures the hemoglobin (Hb) content of individual red cells, calculates the percentage of hypochromic red cells (%Hypo He) and the percentage of hyperchromic red cells (%Hyper He) and quantifies the proportion of marginally sized erythrocytes (%Micro R and %Macro R). The goals of the study were to establish the reference range for erythrocyte extended parameters, their value in different types of anemia and to investigate their reliability in the study of disorders of iron metabolism. MATERIALS Three hundred and ninety samples were analyzed. The Kolmogorov-Smirnoff test, independent samples t-test and Pearson correlation were calculated; receiver operating characteristic (ROC) curve analysis was used to determine their diagnostic performance. RESULTS The values of the four parameters studied were normally distributed and statistically different (p<0.0001) in the different groups of patients; the only exception was %Hypo He in cases of iron deficiency and thalassemia (p=0.3758). Results of ROC curve analysis for %Hypo He in the diagnosis of restricted erythropoiesis reticulocyte Hb content (reticulocyte hemoglobin content, Ret He <29 pg) were: area under the curve 0.963; cut-off 1.8%; sensitivity 98.3%; specificity 91.1%. CONCLUSIONS The new parameters appear to be sensitive for detecting small changes in the number of red cells with inadequate hemoglobinization and volume.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Counting of highly fluorescent ymphocytes (HFLC) as antibody-producing plasma cells on XE-5000

Fluorescence flow cytometry enhances analytical possibilities beyond the normal 5-part differential by providing excellent cluster resolution and separation of abnormal blood cells. A nucleated red blood cell count (NRBC) and an immature granulocyte count (IG) are part of an extended differential on the xe systems with the potential to improve the diagnostic usefulness of the routine 5-part dif...

متن کامل

New Red Cell Parameters on the Sysmex XE-2100 as Potential Markers of Functional Iron Deficiency

The ideal approach to monitor the haematological response of patients with the anaemia associated with chronic renal failure during erythropoietin therapy is controversial. The reticulocyte haemoglobin content (CHr) and percentage hypochromic red cells (% Hypo) may be used as sensitive and specific indicators of functional iron deficiency in clinical situations with otherwise normal red cell in...

متن کامل

New quantitative parameters on a recently introduced automated blood cell counter--the XE 2100.

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count w...

متن کامل

Evaluation of the Formulae Based on Red Blood Cell Indices in Differentiating Between Iron Deficiency Anemia and Beta Thalasemia Minor

Background and Aims: Iron deficiency anemia (IDA) and beta thalassemia minor (BTM) are the most common hypochromic microcytic anemias, and it is regarded important to differentiate between them. several formulae can be taken into consideration based on red blood cell (RBC) parameters in order to distinguish between these two disorders. Hence, the present study intended to evaluate the sensitivi...

متن کامل

Haematological Reference Intervals in a Multiethnic Population

INTRODUCTION Similar to other populations, full blood count reference (FBC) intervals in Malaysia are generally derived from non-Malaysian subjects. However, numerous studies have shown significant differences between and within populations supporting the need for population specific intervals. METHODS Two thousand seven hundred twenty five apparently healthy adults comprising all ages, both ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2009