BACKGROUND Stroke volume variation (SVV) is able to predict adequately the individual response to fluid loading. Our objective was to assess whether the SVV measured by a new algorithm (Vigileo; Flotrac) can predict fluid responsiveness. METHODS Forty mechanically ventilated patients undergoing liver transplantation, who needed volume expansion (VE), were included. VE was done with albumin (4%) 20 mlxBMI over 20 min. SVV, pulse pressure variation (PPV), central venous pressure (CVP), and pulmonary artery occlusion pressure (PAOP) were measured immediately before and after VE. Cardiac output (CO) measured by transthoracic echocardiography (CO-TTE) was used to define responder patients if CO increased by 15% or more after VE, or non-responder otherwise. CO obtained with the pulmonary artery catheter (CO-PAC) and with Vigileo (CO-Vigileo) were also recorded. RESULTS Five patients were excluded. Seventeen patients were responders (Rs) and 18 were non-responders (NRs). Before VE (i) SVV and PPV were higher in Rs and (ii) CVP and PAOP were lower in Rs. Baseline SVV and PPV correlated with change in CO induced by VE (respectively, r(2)=0.72, P<0.0001; r(2)=0.84, P<0.0001). An SVV threshold of >10% discriminated Rs with a sensitivity of 94% and a specificity of 94%. After VE, the decrease in SVV was significantly correlated with the increase in CO (r(2)=0.51; P<0.0001). There was no difference between the area under the ROC curves of SVV and PPV. After VE, the change in CO-Vigileo was closely correlated with change in CO-TTE (r(2)=0.74, P<0.0001) and with change in CO-PAC (r(2)=0.77, P<0.0001). CONCLUSIONS The SVV obtained by the Vigileo system may be used as a predictor of fluid responsiveness in patients with circulatory failure after liver transplantation. CO-Vigileo is able to track the change in CO induced by VE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive leg raising predicts fluid responsiveness in the critically ill.

OBJECTIVE Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN Prospective study. SETTING Medical intensive care unit of ...

متن کامل

Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy

BACKGROUND During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiven...

متن کامل

Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.

Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in H...

متن کامل

Pulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study

INTRODUCTION Pulse pressure variation predicts fluid responsiveness in mechanically ventilated patients passively adapted to the ventilator. Its usefulness in actively breathing ventilated patients was examined only by few studies with potential methodological shortcomings. This study sought to describe the performance of pulse pressure variation as a predictor of fluid responsiveness in hypote...

متن کامل

Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.

BACKGROUND We studied respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak-CA) measured by pulsed wave Doppler ultrasound as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. METHODS Forty patients undergoing elective coronary artery bypass surgery were enrolled. Subjects were classified as responders if stroke volume i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 101 6  شماره 

صفحات  -

تاریخ انتشار 2008