Artificially increasing intraocular pressure causes flicker sensitivity losses.
نویسندگان
چکیده
It has been reported that psychophysical flicker sensitivity, electroretinogram (ERG), pattern electroretinogram (P-ERG), and visual evoked cortical potential (VECP) responses are affected by ocular hypertension and glaucoma. Moreover, it has also been revealed that artificially augmented intraocular pressure (IOP) impairs electrophysiologic responses. In this investigation the authors varied the levels of IOP of ten normal subjects and determined their flicker sensitivities at these levels. Temporarily elevated IOPs were produced by exerting pressure on the eyeball through the eyelids by a new type of ophthalmodynamometer. The results obtained showed that increasing IOP produced loss of flicker sensitivity. For an IOP of 27.2 +/- 2.1 mm Hg, significant losses occurred in the range of frequencies lower than 20 Hz. For a higher IOP (40.7 +/- 2.1 mm Hg) the loss was significantly at frequencies higher than 5 Hz. However, the critical flicker frequency was not affected significantly at either level of IOP. The authors also discovered a phenomenon, called "curtain phenomenon," in that for a critical level of IOP, a high flicker frequency stimulus could completely fade out. The authors' results suggest that the psychophysical flicker sensitivity measurement is a more sensitive technique for the investigation of the effect of the variation of the IOP and that the curtain phenomenon constitutes an interesting indication for additional study of the ocular hypertension mechanism.
منابع مشابه
Flicker sensitivity and cardiovascular function in healthy middle-aged people.
OBJECTIVE To establish normative relations between measures of visual function and cardiovascular variables that are important for age-related disease, including various forms of glaucoma. METHODS Foveal flicker sensitivities, resting blood pressures and heart rates, and intraocular pressures were measured in 18 individuals aged 40 to 68 years. All subjects had 20/20 or better visual acuity i...
متن کاملComparison of Intraocular Pressure of Both Eyes in Patients with Unilateral Pseudoexfoliation Syndrome
Background & Aims: Pseudoexfoliation syndrome (PXS) is a complex disorder which causes an increase in intraocular pressure (IOP). This study was conducted in order to compare IOP of both eyes of patients with unilateral PXS. Methods: In a cross-sectional study from January 2011 to June 2012, 79 patients with unilateral PXS were studied. The patients were examined first with constricted, and the...
متن کاملFunctional characterization of retina and optic nerve after acute ocular ischemia in rats.
PURPOSE To functionally characterize the status of the rat retina and optic nerve after acute elevation of intraocular pressure (IOP) and to determine the dynamics of the pathologic changes in the ischemic retina and optic nerve. METHODS Retinal ischemia was induced in rats by acutely increasing the IOP (110 mm Hg/60 minutes). Direct and indirect pupil light reflexes (PLRs) were recorded from...
متن کاملPsychophysical investigations of the temporal modulation sensitivity function in amblyopia: spatiotemporal interactions.
Temporal modulation sensitivity functions were measured in response to counterphase sine-wave gratings of various spatial frequencies in seven strabismic and/or anisometropic amblyopes and in two stimulus-deprivation amblyopes. Both movement/flicker and pattern detection thresholds were determined. Strabismic and/or anisometropic amblyopes showed reduced sensitivity for movement/flicker and pat...
متن کاملShort-term increase of intraocular pressure does not alter the response of retinal and optic nerve head blood flow to flicker stimulation.
PURPOSE It has been shown that stimulation with diffuse luminance flicker induces vasodilatation in the human retina and increases optic nerve head (ONH) blood flow. The present study was designed to investigate the influence of a short-term increase in intraocular pressure on flicker-induced changes in ONH blood flow and retinal vessel diameters. METHODS In a group of 15 healthy volunteers, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 31 8 شماره
صفحات -
تاریخ انتشار 1990