Suitability of caspofungin for aerosol delivery: physicochemical profiling and nebulizer choice.

نویسندگان

  • Annie Wong-Beringer
  • Maria Polikandritou Lambros
  • Paul M Beringer
  • David L Johnson
چکیده

BACKGROUND Aerosolized antifungal therapy is a promising route of drug delivery for pulmonary aspergillosis due to attainment of high localized concentrations. Caspofungin, a new antifungal agent with proven efficacy against invasive aspergillosis, has ideal potential for aerosolization. STUDY OBJECTIVE To examine in vitro the suitability of caspofungin for aerosol administration by characterizing factors that influence efficacy and airway tolerance of aerosol delivery: physicochemical properties, aerodynamics of drug particles, and efficiency of nebulizing systems. DESIGN Physicochemical characteristics of caspofungin solutions (10 mg/mL and 30 mg/mL) were analyzed: osmolality, pH, viscosity, and surface tension. A time-of-flight aerosol spectrometer API Aerosizer was used to determine aerosol particle size and distribution. Drug output was quantified by high-performance liquid chromatography assay. Nebulizer efficiency was measured by drug output and respirable fraction (percentage of aerosolized particles with a 1 to 5 mum aerodynamic diameter) and compared among three jet nebulizer/compressor systems: device 1, Micromist (Hudson RCI; Temecula, CA)/Pulmo-Aide (model 5650D; DeVilbiss; Somerset, PA); device 2, Sidestream MS 2400/Envoy model IRC 1192 (Invacare; Elyria, OH); and device 3, Pari LC Star/Proneb Ultra (Pari Respiratory Equipment; Midlothian, VA). MEASUREMENTS AND RESULTS Caspofungin requires 0.9% NaCl rather than sterile water as the diluent and addition of 0.3N NaOH buffer to adjust acidity of solutions (pH 6.17 to 6.26) in order to achieve optimal physicochemical properties for airway tolerability (osmolality, 150 to 550 milliosmol per kilogram; chloride ion, 31 to 300 mmol/L; and pH 7.4). The drug output rate increased with higher concentrations of drug solution: device 1, 4.0 mg/min vs 12.5 mg/min; device 2, 5.4 mg/min vs 14.7 mg/min; and device 3, 2.3 mg/min vs 12 mg/min, respectively. The percentage of particles within the respirable range varies depending on device and concentration of drug solutions (10 mg/mL vs 30 mg/mL): device 1, 85% vs 38%; device 2, 44% vs 57%; and device 3, 83% vs 93%, respectively. CONCLUSION Caspofungin solution with adjustments appears to have physicochemical and aerodynamic characteristics suitable for aerosolization when used with either the Pari LC Star/Proneb Ultra or Micromist/Pulmo-Aide devices. Further in vivo testing is warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

In vitro characterization of the I-neb Adaptive Aerosol Delivery (AAD) system.

The in vitro characterization of device-related parameters such as the rate of aerosol output, total aerosol output, particle size, and fine particle fraction, is essential when assessing the potential performance of a nebulizer or making comparisons with other nebulizers as they are indicative of potential clinical performance. This article reviews a number of in vitro studies designed to char...

متن کامل

Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.

BACKGROUND The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE To determine the influence of nebulizer position and bias flow with a jet...

متن کامل

Aerosol delivery of ferulic acid-loaded nanostructured lipid carriers: A promising treatment approach against the respiratory disorders

Introduction: Treatment of lung diseases is one of the major healthcare challenges. Ferulic acid (FA), a phenolic compound with well-established antioxidant and anti-inflammatory properties, has shown promising therapeutic potential against the pulmonary disorders; however, low bioavailability may negatively affect its efficiency. This, prompted us to incorporate FA into the nanostructured ...

متن کامل

In vitro evaluation of radio-labeled aerosol delivery via a variable-flow infant CPAP system.

BACKGROUND Nasal CPAP is widely used in neonatal ICUs. Aerosolized medications such as inhaled steroids and β agonists are commonly administered in-line through nasal CPAP, especially to infants with bronchopulmonary dysplasia. We hypothesized that aerosol delivery to the lungs via variable-flow nasal CPAP in an in vitro model would be unreliable, and that the delivery would depend on the posit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 128 5  شماره 

صفحات  -

تاریخ انتشار 2005