  • M H Weil
چکیده

Float catheterisation of the pulmonary artery was described in The Lancet by Dr R D Bradley (as he then was) in 1964 at a time when invasive circulatory monitoring was almost non-existent outside cardiac surgical units, and ‘intensive care’ was a term barely in use. Cardiac catheterisation was laboratory based and required radiological control: management of acute circulatory crises relied on clinical assessment alone. Dr Bradley recognised the diagnostic and therapeutic value which might accrue from knowledge of central circulatory variables, and used the flow of the circulation itself to direct a fine nylon tube (ID 0.5mm) through the heart and into the pulmonary artery. The catheter was introduced through a short nylon cannula inserted most often in an antecubital vein using the Seldinger technique. A similar cannula in the brachial artery provided not only far more reliable measurement of low arterial pressure than can be achieved with a sphygmomanometer but also permitted display of the arterial waveform, itself of value in interpreting circulatory dynamics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Evaluation of the Effect of Atenolol Induced Depression in Cardiac Output on Its Own Excretion through Urine Analysis

The role of Pharmacist in making the therapeutic decisions for safe and effective therapy is increasing all over the world. However, there are many aspects of drugs in making these decisions that are less commonly studied such as the correlation of cardiac output with pharmacokinetics of drugs. The cardiac output, besides the other factors, is also affected by drugs like atenolol. Therefore, th...

متن کامل

Evaluation of the Effect of Atenolol Induced Depression in Cardiac Output on Its Own Excretion through Urine Analysis

The role of Pharmacist in making the therapeutic decisions for safe and effective therapy is increasing all over the world. However, there are many aspects of drugs in making these decisions that are less commonly studied such as the correlation of cardiac output with pharmacokinetics of drugs. The cardiac output, besides the other factors, is also affected by drugs like atenolol. Therefore, th...

متن کامل

Transoesophageal Doppler echocardiographic measurement of cardiac output by the mitral annulus method.

OBJECTIVE To compare cardiac output measured by the transoesophageal Doppler and thermodilution techniques. DESIGN Prospective direct comparison of paired measurements by both techniques in each patient. SETTING Intensive care unit in a cardiovascular centre. PATIENTS 65 patients after open heart surgery (mean (SD) age 53 (12) years). INTERVENTIONS Cardiac output was measured simultaneo...

متن کامل

Ultrasonic Cardiac Output Measurement for Non- Invasive Cardiac Output Monitoring: Update and Lit- Erature Review

In this article, we review use and clinical utility of the Ultrasonic Cardiac Output Monitor, manufactured in Australia, which was first introduced clinically in 2001. It is non-invasive, requires only a low cost and allows for bedside examination, all of which make this tool potentially useful for patients in emergency departments and intensive care units. Its uses include triage, differential...

متن کامل

Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.

The accuracy and reproducibility of indirect measurement of cardiac output at rest by the carbon dioxide rebreathing (indirect Fick) method with an automated respiratory analysis system (Gould 9000IV) were compared with simultaneous measurements made in duplicate by dye dilution and thermodilution in 25 patients having cardiac catheterisation studies. Measurements of cardiac output by the carbo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care medicine

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1977