In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semiautomatically in maximum intensity projections (MIPs) of contrast-enhanced T1-weighted 3D spoiled gradient-echo datasets, studied with digital subtraction techniques. In vivo, the complete peripheral arterial bed of six patients was studied, from the aorto-iliac bifurcation down to the distal run-off. By measuring the signal intensity (SI) over the lumen of a vessel in the MIP, an SI-plot was obtained. Next, the vessel boundaries were determined using a threshold algorithm; from these boundary points individual diameter values could be obtained along the trajectory of the vessel. In an in vitro study, an optimal threshold value of 30% of the range of SI-values between the background and the maximal SI in the vessel was obtained for accurate diameter measurement in Gd CE MRA (i.e., full-width 30%-maximum). Furthermore, the relationship between the accuracy of these measurements and the scan resolution was investigated. Accuracy was found to be acceptable (i.e., less than 10% over/underestimation) for vessel sizes covering at least 3 pixels. In six patients, diameters were measured in MIPs of the total datasets (i.e., DT) as well as in selective MIPs of the clipped datasets (i.e., DS) (n 5 209). DT and DS were statistically significantly correlated (p , 0.01) with a Pearson correlation coefficient rP 5 0.98. Measurements in the total MIPs yielded statistically significant (p , 0.01) smaller diameter values compared with measurements in selective MIPs, with a mean difference of 0.15 mm. Diameter values from the selective MIPs of the aorto-iliac arteries were also compared with diameter values measured at corresponding anatomic positions in X-ray angiograms of these patients (i.e., DX) (n 5 70). DX and DS were statistically significantly correlated (p , 0.01) with a Pearson correlation coefficient rP 5 0.92. Diameters measured in the selective MIPs were smaller than those measured in the X-ray angiograms (mean difference 0.49 mm) and this difference was statistically significant (p , 0.01). In conclusion, diameter values can be evaluated accurately in MIPs of vessels with at least 3 pixels in diameter, using the full-width 30%-maximum criterion. © 2000 Elsevier Science Inc. All rights reserved.
منابع مشابه
Pii: S0730-725x(00)00154-5
We describe an MR-compatible ventilator that is computer controlled to generate a variety of breathing patterns, to minimize image degrading effects of breathing motion, and to support delivery of gas anesthesia and experimental inhalational gases. A key feature of this ventilator is the breathing valve that attaches directly to the endotracheal tube to reduce dead volume and allows independent...
متن کاملPii: S0730-725x(00)00153-3
In this study the noise sensitivity of various anisotropy indices has been investigated by Monte-Carlo computer simulations and magnetic resonance imaging (MRI) measurements in a phantom and 5 healthy volunteers. Particularly, we compared the noise performance of indices defined solely in terms of eigenvalues and those based on both the eigenvalues and eigenvectors. It is found that anisotropy ...
متن کاملPii: S0730-725x(00)00122-3
We investigated the effects of transcranial magnetic stimulation (TMS) coils and electroencephalographic (EEG) electrodes on T2*-weighted echo-planar images (EPI) at 2.0 T (gradient-echo EPI, mean TE 5 53 ms, 2 3 2 3 4 mm ). In comparison with anatomic gradient-echo images (3D FLASH, TE 5 4 ms, 1 3 1 3 1 mm), T2*-weighted EPI acquisitions of a water-filled spherical phantom revealed severe sign...
متن کاملPii: S0730-725x(01)00428-3
The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...
متن کاملPii: S0730-725x(99)00102-2
Exploratory data-driven methods such as Fuzzy clustering analysis (FCA) and Principal component analysis (PCA) may be considered as hypothesis-generating procedures that are complementary to the hypothesis-led statistical inferential methods in functional magnetic resonance imaging (fMRI). Here, a comparison between FCA and PCA is presented in a systematic fMRI study, with MR data acquired unde...
متن کاملPii: S0730-725x(00)00231-9
The objective of this study was to detect auditory cortical activation in non-sedated neonates employing functional magnetic resonance imaging (fMRI). Using echo-planar functional brain imaging, subjects were presented with a frequency-modulated pure tone; the BOLD signal response was mapped in 5 mm-thick slices running parallel to the superior temporal gyrus. Twenty healthy neonates (13 term, ...