A duality based algorithm for multileaf collimator field segmentation with interleaf collision constraint

نویسنده

  • Thomas Kalinowski
چکیده

Intensity maps are nonnegative matrices describing the intensity modulation of beams in radiotherapy.An important step in the planning process is to determine a segmentation, that is a representation of an intensity map as a positive combination of special matrices corresponding to fixed positions of the multileaf collimator, called segments. We consider the problem of constructing segmentations with small total numbers of monitor units and segments. Generalizing the approach of Engel [Discrete Appl. Math., in press, doi:10.1016/j.dam.2004.10.007] so that it applies to the segmentation problem with interleaf collision constraint, we show that the minimal number of monitor units in this case can be interpreted as the maximal length of a path in a layered digraph. We derive an efficient algorithm that constructs a segmentation with this minimal number of monitor units, and we propose a heuristic approach to the reduction of the number of segments. © 2005 Elsevier B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Approximated MLC shape matrix decomposition with interleaf collision constraint

Shape matrix decomposition is a subproblem in radiation therapy planning. A given fluence matrix A has to be decomposed into a sum of shape matrices corresponding to homogeneous fields that can be shaped by a multileaf collimator (MLC). We solve the problem of minimizing the delivery time for an approximation of A satisfying certain prescribed bounds, under the additional condition that the use...

متن کامل

A minimum cost flow formulation for approximated MLC segmentation

Shape matrix decomposition is a subproblem in radiation therapy planning. A given fluence matrix A has to be written as a sum of shape matrices corresponding to homogeneous fields that can be shaped by a multileaf collimator (MLC). We solve the problem to find an approximation B of A satisfying prescribed upper and lower bounds for each entry. The approximation B is determined such that the cor...

متن کامل

Using multileaf collimator interleaf leakage to extract absolute spatial information from electronic portal imaging device images

Electronic portal imaging devices (EPIDs) are potentially valuable tools for linear accelerator quality assurance and for measuring and analyzing geometric variations in radiation treatment delivery. Geometric analysis is more robust if referenced against an absolute position such as the isocenter (collimator axis of rotation), allowing the observer to discriminate between various setup errors ...

متن کامل

Evaluation of a dual-level four-bank micro multileaf collimator in reducing dose undulation, leakage, and transmission

This study was to evaluate the reduction of dose undulation at the field edge, gap leakage and interleaf transmission by utilizing a dual-level four-bank micro multileaf collimator (mMLC) and compare with standard MLC. Method and Materials: A 6MV Varian 600C linear accelerator has been collimated with a dual-level fourbank mMLC. The dual mMLC consists of four banks of leaves with upper and lowe...

متن کامل

Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...