Prominent harmonics in IT offices are essentially due to the presence of SMPS in computers large numbers. In a three-phase, fourwire system, current harmonics leads to flow zero sequence current in neutral conductor, increased losses in motors, false tripping of circuit breakers. In this paper, VSI is designed as a compensator based instantaneous reactive power theory. And is used to mitigate the current harmonic caused by 6 pulse diode rectifier is mitigated. Simulation is done with MATlab software and results are verified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On design and implementation of three phase three level shunt active power filter for harmonic reduction using synchronous reference frame theory

Shunt active power filter is commonly used to eliminate current harmonics generated in the source side due to presence of non-linear loads. This scheme consists of three phase three level diode clamped multilevel inverter and a DC capacitor that act as a shunt active power filter to mitigate the supply current harmonics and inject the required reactive power to non-linear loads. In this paper, ...

متن کامل

Seamless Grid Synchronization of a Proportional+Resonant Control-Based Voltage Controller Considering Non-Linear Loads under Islanded Mode

This paper proposes the grid synchronization method of inverter using a quasi Proportional+Multi Resonant (P+MR) control-based voltage controller a stationary reference frame. The inverter supplies a non-linear load under the islanded mode. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without a connection to the grid. On the other hand, if t...

متن کامل

A Practical Approach to Harmonic Compensation in Electrical Power Systems – Using Shunt Active Power Filter

The Shunt active power filters are used in power systems for the compensation of harmonic currents generated for non linear loads. A reference current estimation method for control of SAPF using a digital filter based synchronous reference frame theory is presented. To extract the fundamental component of source current, the synchronous reference frame (SRF) theory is suitable because of its ea...

متن کامل

Harmonic Compensation using STATCOM for SEIG Feeding Single-Phase Load Connected between Different Phases

The paper presents the analysis of harmonic distortion when non-linear load is connected in different phases of power system with STATCOM for singly excited induction generator system with wind turbine as prime mover. Now-a-days due to the drastically increased in use of non linear loads causes many power quality problems in power system network. Those problems are classified as reactive power ...

متن کامل

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...