Restoration of Low-Dose Digital Breast Tomosynthesis
نویسندگان
چکیده
In breast cancer screening, the radiation dose must be kept to the minimum necessary to achieve the desired diagnostic objective, thus minimizing risks associated with cancer induction. However, decreasing the radiation dose also degrades the image quality. In this work we restore digital breast tomosynthesis (DBT) projections acquired at low radiation doses with the goal of achieving a quality comparable to that obtained from current standard full-dose imaging protocols. A multiframe denoising algorithm was applied to low-dose projections, which are filtered jointly. Furthermore, a weighted average was used to inject a varying portion of the noisy signal back into the denoised one, in order to attain a signal-to-noise ratio comparable to that of standard full-dose projections. The entire restoration framework leverages a signal-dependent noise model with quantum gain which varies both upon the projection angle and on the pixel position. A clinical DBT system and a 3D anthropomorphic breast phantom were used to validate the proposed method, both on DBT projections and slices from the 3D reconstructed volume. The framework is shown to attain the standard full-dose image quality from data acquired at 50% lower radiation dose, whereas progressive loss of relevant details compromises the image quality if the dosage is further decreased.
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملDigital breast tomosynthesis: a pilot observer study.
OBJECTIVE The objective of our study was to assess ergonomic and diagnostic performance-related issues associated with the interpretation of digital breast tomosynthesis-generated examinations. MATERIALS AND METHODS Thirty selected cases were read under three different display conditions by nine experienced radiologists in a fully crossed, mode-balanced observer performance study. The reading...
متن کاملSimulation of Dose Reduction in Digital Breast Tomosynthesis
Clinical evaluation of dose reduction studies in x-ray breast imaging is problematic because it is difficult to justify imaging the same patient at a variety of radiation doses. One common alternative is to use simulation algorithms to manipulate a standard-dose exam to mimic reduced doses. Although there are several dose-reduction simulation methods for full-field digital mammography, the avai...
متن کاملRadiation dosimetry in digital breast tomosynthesis: report of AAPM Tomosynthesis Subcommittee Task Group 223.
The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important ...
متن کاملComparison of Different Reconstruction Algorithms for Decreasing the Exposure Dose during Digital Breast Tomosynthesis: A Phantom Study
We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose and image quality, for exploring the possibility of decreasing the radiation dose during digital breast tomosynthesis (DBT). The three algorithms were implemented using a DBT syst...