Air quality monitoring in a neonatal intensive care unit.

نویسندگان

  • K Toyooka
  • H Miyazawa
  • Y Naiki
  • Y Ishii
  • F Nishiyama
  • T Kuratsuji
  • T Kirikae
چکیده

Air sampling in health care facilities, especially in specialcare areas such as neonatal intensiv? care units (NICUs), should be done on a periodic basis ln Order to determine indoor air quality, efficacy of dust control measures, or airhandling system performance. (The draft guideline is available with the full text of this article at http://www.cdc.gov/ ncidod/hip/enviro/env_guide_draft.pdf) ( 1 ). A practical method to assess Fir qualityis to monitor airborne particles with in a certaln Size range using particle counters (2). Airbome particles and wind speed were continuously monitored in an NICU with five beds from 0:00 to 18:00 0n weekdays. The NICU was 199.6 m3 in size (76.75 m2floor space by 2.6 m high), and equipped with an anteroom of21. 1 m3 (8.1 m2floor space by 2.6 m high) and a fixed dusted room-air recirculation system with 85.4 % retum. As shown in a sketch of the NICU (Fig. I), four air-supply vents were located in the ceiling and fittedwith high-efficiency particulate air (HEPA) filters for air cleaning・ Two air-exhaust vents were located near the floor ln two comers and three were located in the ceiling. The volume of air supply was 4,800 m3/h, and the air changed 24 times per hour. In the room were seven incubators,including two spares,and five monitonng equlPment units, respirators, a radiant warmer, several shelves for solutions, medical supplies, records, and other materials. Air-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the Performance of Nurses in the Proper Adjustment of Monitoring Instruments in the Neonatal Intensive Care Unit

Background: Monitoring serves to maintain physiologic variables within normal limits and when a parameter crosses a set threshold, an alarm is triggered. Therefore, this study aimed to determine whether alarm limits are properly adjusted in the neonatal intensive care unit (NICU) by nursing staff or not.Methods: The data concerning alarm limits corresponding to the three shifts of nursing...

متن کامل

Correlations of Handling Procedures and Sleep Patterns of the Infants Admitted to the Neonatal Intensive Care Unit

Background: The present study aimed to assess handling procedures and their effects on the sleep-wake time in the preterm infants admitted to the neonatal intensive care unit (NICU). Methods: This observationalcross-sectional study was conducted in the NICU ofVali-e-Asr Teaching Hospital affiliated to Tehran University of Medical Sciences (TUMS), Iran in 2016. Sample population consisted of 15...

متن کامل

Correlation between Quality of Care and Length of Hospital Stay in Neonatal Intensive Care Unit

Background: Length of hospital stay (LHS) is the most important and practical indicator in hospitals, which largely reflects the level of hospital performance and activity. It is also an important indicator for resource planning. Moreover, the quality of care can theoretically be related to LHS. The aim of this study was to investigate the relationship between LHS and quality of nursing care in...

متن کامل

Audit nursing reports in intubated neonates admitted in neonatal intensive care unit of Ayatollah Rouhani Hospital, Babol, Iran

Background: Accurate and complete documentation of nursing records is one of the preconditions of the evidence-based cares and is considered as one of the most important professional tasks in nursing. The aim of the present study was to audit the nursing reports in intubated neonates admitted in neonatal intensive care unit of Ayatollah Rouhani hospital, Babol. Methods: In this cross-section...

متن کامل

Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit

Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Japanese journal of infectious diseases

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2001