Conduction Abnormalities after Transcatheter Aortic Valve Implantation and Diastolic Dysfunction.

نویسندگان

  • Ofir Priesler
  • Simon Biner
  • Ariel Finkelstein
  • Yoav Michowitz
چکیده

OBJECTIVES Transcatheter aortic valve implantation (TAVI) is frequently associated with the development of conduction abnormalities. We assessed the effect of conduction abnormalities on diastolic function following TAVI. METHODS In total, 101 consecutive post-TAVI patients were included, each with echocardiographic follow-up at 1 and 6 months. Diastolic properties were correlated with the occurrence of a long PR interval and wide QRS, and their change from baseline. The measured diastolic parameters included E/A ratio, E wave deceleration time, E wave to e' ratio, left atrial (LA) volume, and systolic pulmonary artery pressure (SPAP). The clinical outcome was all-cause mortality. RESULTS Overall, TAVI was associated with a consistent decrease in SPAP at the 1- and 6-month follow-up. LA volumes were increased at 1 month post-TAVI in patients with a wide compared to normal QRS (p = 0.03) and at 6 months in patients with a normal compared to prolonged PR (p = 0.03). PR prolongation above 40 ms was associated with lower SPAP at the 1- but not 6-month follow-up. Survival was not influenced by conduction abnormalities. CONCLUSIONS TAVI is associated with a reduction in SPAP. A postprocedural wide QRS and normal PR interval may unfavorably influence the left-sided filling performance, resulting in an increased LA volume. Other diastolic parameters, as well as survival, are not significantly affected by postprocedural conduction abnormalities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conduction abnormalities after transcatheter aortic valve implantation

In the last few years, transcatheter aortic valve implantation (TAVI) has become an alternative procedure in patients with severe aortic stenosis and high risk for surgical aortic replacement. Due to the anatomic correlation between aortic valve structure and conduction system of the heart, one of the most common complications after TAVI is conduction system disturbances which including bundle ...

متن کامل

Peritoneal migration of an epicardial pacemaker.

therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association. Europace 2013;15:1070–118. 20. Urena M, Webb JG, Eltchaninoff H, Munoz-Garcia AJ, Bouleti C, Tamburino C et al. Late cardiac death in patients undergoing transcatheter aortic valve replacement: incidence and predictors of advanced heart failure and sudden cardiac death. J ...

متن کامل

Conduction disturbances after transcatheter aortic valve implantation procedures – predictors and management

Transcatheter aortic valve implantation (TAVI) has become a safe and efficient alternative to cardiac surgery in patients with severe aortic stenosis. In many countries the number of performed TAVI procedures equals the number of surgical implantations. Indications for TAVI are becoming more liberal, allowing a wider spectrum of patients to benefit from the advantages of transcatheter therapy. ...

متن کامل

Immediate recovery of the left atrial and left ventricular diastolic function after transcatheter aortic valve implantation: A transesophageal echocardiography study.

BACKGROUND Chronic increased afterload due to severe aortic stenosis (AS) results in com-pensatory concentric left ventricular (LV) hypertrophy and LV dysfunction. These in turn cause remodeling of the left heart. The aim of this study was to investigate the acute effect of transcatheter aortic valve implantation (TAVI) on left atrial (LA) mechanics and LV diastolic function. METHODS The stud...

متن کامل

Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation.

AIMS Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. METHODS AND RESULTS Sixty-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiology

دوره 137 1  شماره 

صفحات  -

تاریخ انتشار 2017