A method of fixation of endotracheal tubes.
نویسنده
چکیده
Sir,—For prolonged intubation in a children's hospital we prefer to use uncuffed plastic tubes, either Warne* neonatal tubes inserted orally, or nasal/oral bevel tubes introduced nasally. Fixation of these tubes has always been a problem, as adhesive tape irritates the skin and loosens when wet with secretions. With nasal tubes, there is always the danger of dislodgement of the tube connector, with loss of the tube into the pharynx. The JacksonReest tube does overcome some of these difficulties, but we do not often use it because of the thick wall and the need to shorten the tube at the bevel end, which leaves a sharp edge. A new method of fixation has been devised, which has been in use in our intensive therapy unit for a year, and has proved very satisfactory in the opinion of both medical and nursing staff. The length of tube needed must be measured reasonably accurately before its insertion. This may be done by introducing the tube first, then cutting another at the right length and substituting this. The lettering on the Warne tubes forms a useful guide. Alternatively, one may use a formula (Manila et aT, 1971) or chart (Rees and Owen-Thomas, 1966) to judge the length required. A leather punch (obtainable from craft shops) is used, and holes (B, fig. 1) punched in the anterior and posterior walls of the tube at the measured leveL Further holes (A, fig. 1) are then punched about 3 cm proxirnally and at right angles to the first pair. The tube is trimmed, if necessary, beyond the second pair of holes, and scissors used to cut down the anterior and posterior walls of the tube as far as the first holes (fig. 1). A flange is thus formed, and the tube will split no further. A connector, usually of the Cardiff^ type, is fitted into the tube (fig. 2). Tapes are passed through the second pair of holes and attached to a cap made of tube-gauze of appropriate size.
منابع مشابه
Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملExtubation force depends upon angle of force application and fixation technique: a study of 7 methods
BACKGROUND Endotracheal tubes are frequently used to establish alternate airways. Precise placement of the tubes must be maintained to prevent serious complications. Several methods for fixation of endotracheal tubes are available. Available methods vary widely in form and functionality. Due to the unpredictable and dynamic nature of circumstances surrounding intubation, thorough evaluation of ...
متن کاملPediatric cuffed endotracheal tubes: an evolution of care.
PURPOSE To examine the history of pediatric endotracheal intubation and the issues surrounding the change from uncuffed endotracheal tubes to cuffed endotracheal tubes, including pediatric airway anatomy, endotracheal tube design, complications, and safety concerns. METHOD Review of the literature. CONCLUSIONS Although the use of cuffed endotracheal tubes in infants and children remains a t...
متن کاملA Novel Method of Fixation of Tracheostomy Tube in Cervical Spine Surgeries with Posterior Approach
Address for correspondence: Dr. Ankur Khandelwal, Department of Anaesthesiology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Rae Barelly Road, Lucknow ‐ 226 014, Uttar Pradesh, India. E‐mail: [email protected] Sir, Securing of any external devices such as endotracheal tube (ETT), tracheostomy tube (TT), arterial and central venous catheters, nasogastric tubes, drainage tubes...
متن کاملSilver-coated endotracheal tubes associated with reduced bacterial burden in the lungs of mechanically ventilated dogs.
STUDY OBJECTIVES To evaluate the influence of silver-coated endotracheal tubes on the lung bacterial burden of mechanically ventilated dogs. DESIGN Randomized, double-blinded, controlled experiment. SETTING Animal research facility of a regional medical university. PATIENTS OR PARTICIPANTS Eleven healthy adult dogs. INTERVENTIONS The dogs were intubated either with cuffed, noncoated end...