Direct 3D Ultrasound to Video Registration Using Photoacoustic Effect
نویسندگان
چکیده
Interventional guidance systems require surgical navigation systems to register different tools and devices together. Standard navigation systems have various drawbacks leading to target registration errors (TRE) of around 3mm. The aim of this work is to introduce the photoacoustic (PA) effect as a direct 3D ultrasound (US) to video registration method. We present our experimental setup and demonstrate its feasibility on both a synthetic phantom and an ex vivo tissue phantom. We achieve an average TRE of 560 microns and standard deviation of 280 microns on a synthetic phantom. Also, an average TRE of 420 microns and standard deviation of 150 microns on the ex vivo tissue phantom are obtained. We describe a roadmap to bring this system into the surgical setting and highlight possible challenges along the way.
منابع مشابه
Photoacoustic Registration and Visualization
Abstract. Interventional guidance systems require surgical navigation systems to register different tools and technologies together. Standard navigation systems have drawbacks leading to target registration errors (TRE) of around 3mm. This project introduces the photoacoustic (PA) effect as a direct 3D ultrasound (US) to video registration method. We demonstrate its feasibility on both a synthe...
متن کاملDirect three-dimensional ultrasound-to-video registration using photoacoustic markers.
Modern surgical procedures often have a fusion of video and other imaging modalities to provide the surgeon with information support. This requires interventional guidance equipment and surgical navigation systems to register different tools and devices together, such as stereoscopic endoscopes and ultrasound (US) transducers. In this work, the focus is specifically on the registration between ...
متن کاملHigh-resolution photoacoustic microscope for rat brain imaging in vivo
A reflection-mode photoacoustic microscope (PAM) for rat brain imaging in vivo is constructed. A pulsed laser is used as an excitation source, and a focused ultrasound transducer is adopted to collect the photoacoustic signal. Raster scanning is applied to acquire three-dimensional (3D) data. The obtained measurements of the lateral and axial resolutions of the microscope are 45 and 15 μm, resp...
متن کاملIn vivo longitudinal photoacoustic imaging of subcutaneous tumours in mice
Photoacoustic tomography can provide high resolution 3D images of vascular networks, making it well suited to characterising the development of tumour vasculature and its response to treatment. In this study, photoacoustic images to depths of up to 9 mm were obtained using an all optical ultrasound detection scheme. Two type of colorectal tumours (LS174T and SW1222) implanted subcutaneously in ...
متن کاملIn vivo multi-modality photoacoustic and pulse echo tracking of prostate tumor growth using a window chamber
Understanding the tumor microenvironment is critical to characterizing how cancers operate and predicting how they will eventually respond to treatment. The mouse window chamber model is an excellent tool for cancer research, because it enables high resolution tumor imaging and cross-validation using multiple modalities. We describe a novel multimodality imaging system that incorporates three d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 15 Pt 2 شماره
صفحات -
تاریخ انتشار 2012