Measurement of regional myocardial perfusion in man with 133 xenon and a scintillation camera.

نویسندگان

  • P J Cannon
  • R B Dell
  • E M Dwyer
چکیده

A method was devised to quantitate regional capillary perfusion in the human heart by measuring the clearance constants (k) of Xenon-133 washout from multiple areas of the myocardium with a multiple-crystal scintillation camera. In 17 subjects, (133)Xe was injected into the right or left coronary artery or both and counts per second (cps) were recorded simultaneously on magnetic tape from each of 294 scintillation crystals viewing the precordium through a multichannel collimator. Data were processed by a digital computer. Crystals detecting the myocardial washout of (133)Xe were distinguished from those monitoring pulmonary excretion by positioning radioactive markers at the cardiac margins, and by a computer printout of the peak cps recorded by each crystal and its time after isotope injection into the coronary artery. The slopes of the initial segment of the multiple (133)Xe curves obtained in each study were calculated by the method of least squares using a monoexponential model. Myocardial blood flow rates in the cardiac regions viewed by the individual crystals were calculated (assuming a blood to myocardium partition coefficient of 0.72) along with the SD of every flow measurement. The pattern of myocardial perfusion rates so obtained was superimposed over a tracing of the subject's coronary arteriogram. Scintiphotographs showing the arrival and washout of isotope from various regions of myocardium and the area of tissue perfused by each coronary artery were obtained by replaying the data tape on an oscilloscope. Significant regional variations in local myocardial perfusion rates were observed in hearts with normal coronary arteries. When capillary flow measurements from crystals overlying the various cardiac chambers were averaged in each subject, the mean myocardial blood flow rate of the left ventricle in 17 patients, 64.1 +/-13.9 (SD) ml/100 g.min, significantly exceeded that of the right ventricle, 47.8 +/-10.9 ml/100 g.min, and of the right atrial region, 33.6 +/-10.3 ml/100 g.min. The approach may facilitate more objective assessment of: myocardial capillary perfusion in patients with angina pactoris, the pharmacology of antianginal drugs, and the efficacy of surgical procedures to revascularize ischemic myocardium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

jnm / DIAGNOSTIC NUCLEAR MEDICINE

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and ap propriate collimili ion....

متن کامل

A clinical comparison of Xe-127 and Xe-133 for ventilation studies.

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and appropriate collimation. A ...

متن کامل

Visual assessment of regional myocardial perfusion utilizing radioactive xenon and scintillation photography.

A method was devised to visualize the areas of left ventricle supplied by various coronary arterial branches utilizing scintillation photography and an inert radioactive gas which distributes instantaneously between coronary blood and perfused myocardial cells. From 1 to 5 millicuries of 133Xe dissolved in saline solution was injected through a catheter into the anterior descending or posterior...

متن کامل

Regional myocardial blood flow in patients with residual anterior and inferior transmural infarction.

Regional myocardial perfusion rates were estimated in ten patients with a residual transmural anterior wall infarction and ten patients with a residual transmural inferior infarction. The results in these two groups of patients were compared to the regional myocardial perfusion patterns obtained in 25 patients with normal coronary arteriograms who failed to demonstrate any electrocardiographic ...

متن کامل

DIAGNOSTIC NUCLEAR MEDICINE Quantitative Assessment of Ventiiation-Perfusion Mismatch by Radioxenon Imaging of the Lung

By the use of xenon-133 and a scintillation camera with digital data storage and processing system, a topographic relationship between ventilation distribution (P) and perfusion distribution (Q) was examined quantitatively in two groups of normal nonsmokers and one of older smokers, all healthy. In addition, subjects with a variety of cardiopulmonary disease were tested. The fractional regional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 1972