Dual-target function validation of single-particle selection from low-contrast cryo-electron micrographs
نویسندگان
چکیده
Weak-signal detection and single-particle selection from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy (cryoEM) presents a practical challenge. Cryo-EM image contrast degrades as the size of biomolecules of structural interest decreases. When the image contrast falls into a range where the location or presence of single particles becomes ambiguous, a need arises for objective computational approaches to detect weak signal and to select and verify particles from these low-contrast micrographs. Here we propose an objective validation scheme for low-contrast particle selection using a combination of two different target functions. In an
منابع مشابه
On the parameters affecting dual-target-function evaluation of single-particle selection from cryo-electron micrographs
In the analysis of frozen hydrated biomolecules by single-particle cryo-electron microscopy, template-based particle picking by a target function called fast local correlation (FLC) allows a large number of particle images to be automatically picked from micrographs. A second, independent target function based on maximum likelihood (ML) can be used to align the images and verify the presence of...
متن کاملAutomatic post-picking improves particle image detection from Cryo-EM micrographs
Cryo-electron microscopy (cryo-EM) studies using single particle reconstruction is extensively used to reveal structural information of macromolecular complexes. Aiming at the highest achievable resolution, state of the art electron microscopes acquire thousands of highquality images. Having collected these data, each single particle must be detected and windowed out. Several fullyor semi-autom...
متن کاملAPPLE Picker: Automatic Particle Picking, a Low-Effort Cryo-EM Framework
Particle picking is a crucial first step in the computational pipeline of single-particle cryo-electron microscopy (cryo-EM). Selecting particles from the micrographs is difficult especially for small particles with low contrast. As high-resolution reconstruction typically requires hundreds of thousands of particles, manually picking that many particles is often too time-consuming. While semi-a...
متن کاملStructure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction
Cryo-electron microscopy (cryo-EM), combined with image processing, is an increasingly powerful tool for structure determination of macromolecular protein complexes and assemblies. In fact, single particle electron microscopy and two-dimensional (2D) electron crystallography have become relatively routine methodologies and a large number of structures have been solved using these methods. At th...
متن کاملA binary segmentation approach for boxing ribosome particles in cryo EM micrographs.
Three-dimensional reconstruction of ribosome particles from electron micrographs requires selection of many single-particle images. Roughly 100,000 particles are required to achieve approximately 10 A resolution. Manual selection of particles, by visual observation of the micrographs on a computer screen, is recognized as a bottleneck in automated single-particle reconstruction. This paper desc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013