A 3D MRI-Based Cardiac Computer Model to Study Arrhythmia and Its In-vivo Experimental Validation

نویسندگان

  • Mihaela Pop
  • Maxime Sermesant
  • Jean-Marc Peyrat
  • Eugene Crystal
  • Sudip Ghate
  • Tommaso Mansi
  • Ilan Lashevsky
  • Beiping Qiang
  • Elliot R. McVeigh
  • Nicholas Ayache
  • Graham A. Wright
چکیده

The aim of this work was to develop a simple and fast 3D MRI-based computer model of arrhythmia inducibility in porcine hearts with chronic infarct scar, and to further validate it using electrophysiology (EP) measures obtained in-vivo. The heart model was built from MRI scans (with voxel size smaller than 1mm) and had fiber directions extracted from diffusion tensor DT-MRI. We used a macroscopic model that calculates the propagation of action potential (AP) after application of a train of stimuli, with location and timing replicating precisely the stimulation protocol used in the in-vivo EP study. Simulation results were performed for two infarct hearts: one with noninducible and the other with inducible ventricular tachycardia (VT), successfully predicting the study outcome like in the in-vivo cases; for the inducible heart, the average predicted VT cycle length was 273ms, compared to a recorded VT of approximately 250ms. We also generated synthetic fibers for each heart and found the associated helix angle whose transmural variation (in healthy zones) from endoto epicardium gave the smallest difference (i.e., approx. 41°) when compared to the helix angle corresponding to fibers from DW-MRI. Mean differences between activation times computed using DT-MRI fibers and using synthetic fibers for the two hearts were 6 ms and 11 ms,

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Experimental Framework to Validate 3D Models of Cardiac Electrophysiology Via Optical Imaging and MRI

Our aim is to develop a framework to validate 3-D computer models of cardiac electrophysiology using measurements of action potential obtained via optical imaging (based on voltage-sensitive fluorescence), and heart anatomy and fiber directions which are obtained from magnetic resonance imaging (MRI). In this paper we present preliminary results of this novel framework using a healthy porcine h...

متن کامل

Effects of Doxycycline on Cx43 Distribution and Cardiac Arrhythmia Susceptibility of Rats after Myocardial Infarction

Effects of Doxycycline on Cx43 Distribution and Cardiac Arrhythmia Susceptibility of Rats after Myocardial Infarction Abstract: This study aimed to observe the effects of doxycycline (DOX) on gap junction remodeling after MI and the susceptibility of rats to cardiac arrhythmia. The proximal left anterior descending coronary artery of rats was ligated to establish a myocardial infarction animal...

متن کامل

Effects of Doxycycline on Cx43 Distribution and Cardiac Arrhythmia Susceptibility of Rats after Myocardial Infarction

Effects of Doxycycline on Cx43 Distribution and Cardiac Arrhythmia Susceptibility of Rats after Myocardial Infarction Abstract: This study aimed to observe the effects of doxycycline (DOX) on gap junction remodeling after MI and the susceptibility of rats to cardiac arrhythmia. The proximal left anterior descending coronary artery of rats was ligated to establish a myocardial infarction animal...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011