Feedback-controlled constant-pressure anterior chamber perfusion in live mice

نویسندگان

  • Minhee K. Ko
  • Aleksandr Yelenskiy
  • Jose M. Gonzalez
  • James C. H. Tan
چکیده

PURPOSE To describe live mouse, anterior chamber constant-pressure perfusion by an approach using feedback-controlled coupling of pressure and flow to maintain a preset pressure. METHODS We established a microperfusion system that maintains a constant preset pressure in the anterior chamber of live mice by automatically regulating the microsyringe pump flow rate with a computer-controlled voltage feedback loop. Perfusion was by single-needle cannulation. We characterized the following in C57BL/6 mice aged 3-4 months in vivo: (i) pressure stability, (ii) pressure and flow rate reproducibility, (iii) total outflow facility, and (iv) anterior segment histology after perfusion. RESULTS Twenty live mice underwent perfusion. Constant pressure was quickly attained and stably maintained. The coefficient of pressure variation over time during perfusion at a preset pressure was <0.001. The average coefficient of variation for repeat pressure and flow rate measurements was 0.0005 and 0.127, respectively. The relationship between flow rate and pressure was linear for perfusions between 15 and 35 mmHg. The total outflow facility was 0.0066 µl/min/mmHg. Perfusion system resistance (0.5 mmHg/min/µl) was negligible relative to the ocular outflow resistance (147 mmHg/min/µl) at physiologically relevant perfusion pressures of 15-35 mmHg. No histological disruption of the drainage tissue was seen following perfusion. CONCLUSIONS Predetermined pressure was stably maintained during constant-pressure perfusion of live mouse eyes by a method using feedback-controlled coupling of pressure and flow along with single-needle anterior chamber cannulation. Perfusion measurements were reproducible. This approach is potentially useful for exploring aqueous drainage tissue biology, physiology, and pharmacology in live mice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical Factors Affecting Outflow Facility Measurements in Mice.

PURPOSE Mice are commonly used to study conventional outflow physiology. This study examined how physical factors (hydration, temperature, and anterior chamber [AC] deepening) influence ocular perfusion measurements in mice. METHODS Outflow facility (C) and pressure-independent outflow (Fu) were assessed by multilevel constant pressure perfusion of enucleated eyes from C57BL/6 mice. To examin...

متن کامل

Ocular hypothermia: anterior chamber perfusion.

The anterior chambers of 27 rabbit eyes were perfused at constant pressure with room temperature (25 degrees C) or cooled (11 degrees C) balanced salt solution at constant flow rates of 4.8 ml/min or 8.5 ml/min. Intraocular temperature changes in the anterior chamber, anterior vitreous, mid vitreous, and posterior vitreous and on the retina surface were monitored with an intraocular thermocoupl...

متن کامل

Effect of repeated anterior chamber perfusion on intraocular pressure and total outflow facility in the cynomolgus monkey.

Total outflow facility was determined by two-level constant pressure perfusion of the anterior chamber in surgically virgin, aniridic, and ciliary muscle disinserted cynomolgus monkey eyes 6 to 13 times at 1- to 2-month intervals over periods of 8 to 24 months. Facility decreased approximately 15 to 20% between consecutive thirds of the perfusion history, independent of eye type. The facility d...

متن کامل

The relationship of pressure and aqueous outflow in enucleated human eyes.

The influence of intraocular pressure on resistance to aqueous outflow was evaluated in enucleated normal and glaucomatous human eyes by quantitative aqueous perfusion of the anterior chamber. When provision was made for free communication from anterior to posterior chamber to avoid artificial deepening of the anterior chamber, and the intraocular pressure was raised stepwise from 5 to 50 mm. H...

متن کامل

Influence of intraocular pressure on aqueous outflow facility in enucleated eyes of different mammals.

Freshly enucleated monkey, calf, and human eyes were quantitatively perfused with mock aqueous humor through the anterior chamber by a constant pressure technique. After baseline perfusion at 15 mm Hg, intraocular pressure was raised to 45 mm Hg and later reduced back to 15 mm Hg. Calf and human (both adult and infant) eyes had lower outflow facilities at 45 than at 15 mm Hg. However, four type...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2014