Detection of Local Recurrence of Prostate Cancer After Radical Prostatectomy Using Endorectal Coil MRI at 3 T: Addition of DWI and Dynamic Contrast Enhancement to T2-Weighted MRI.

نویسندگان

  • Kazuhiro Kitajima
  • Robert P Hartman
  • Adam T Froemming
  • Clinton E Hagen
  • Naoki Takahashi
  • Akira Kawashima
چکیده

OBJECTIVE The purpose of this study was to assess the utility of DWI and dynamic contrast enhancement (DCE) in MRI at 3 T with an endorectal coil in identifying local prostate cancer recurrence after radical prostatectomy. MATERIALS AND METHODS Eighty men underwent MRI for suspected local recurrence. The reference standards were histopathologic result, decrease in prostate-specific antigen level after salvage radiation therapy, and follow-up findings. Using a 5-point scoring system, two reviewers independently interpreted T2-weighted images alone (protocol A), a combination of T2-weighted and DW images (protocol B), a combination of T2-weighted and DCE images (protocol C), and a combination of T2-weighted, DW, and DCE images (protocol D). ROC analysis was used to compare the four protocols. RESULTS Local recurrence was found in 57 of the 80 patients (71.3%). The ROC AUCs for protocols A, B, C, and D were 0.71, 0.72, 0.90, and 0.89 for reader 1 and 0.65, 0.62, 0.84, and 0.83 for reader 2. Protocols C and D had statistically better performance than protocols A and B for both readers (p < 0.001). For local recurrence lesions with a long-axis diameter less than 10 mm visualized with protocol C, protocol B had detection rates of 25.0-29.4% and for lesions measuring 10 mm or greater, 67.9-69.0%. The rates of detection of local recurrence with protocol C or D were 76.5-82.4% for prostate-specific antigen levels less than 0.4 ng/mL, 60-73.3% for 0.4-1.0 ng/mL, and 80-88.0% for greater than 1.0 ng/mL. CONCLUSION Addition of DCE to T2-weighted imaging in 3-T MRI with an endorectal coil improves the accuracy of detection of local cancer recurrence after radical prostatectomy. The addition of DWI is of limited incremental value for detection, especially of small lesions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of local recurrent prostate cancer after radical prostatectomy in terms of salvage radiotherapy using dynamic contrast enhanced-MRI without endorectal coil

PURPOSE To evaluate the value of dynamic contrast enhanced Magnetic Resonance Imaging (DCE-MRI) without endorectal coil (EC) in the detection of local recurrent prostate cancer (PC) after radical prostatectomy (RP). MATERIAL AND METHODS Thirty-three patients with recurrent PC underwent DCE-MRI without EC before salvage radiotherapy (RT). At median 15 (mean 16±4.9, range 12-27) months after co...

متن کامل

Usefulness of a Combined Approach of T1-Weighted, T2-Weighted, Dynamic Contrast-Enhanced, and Diffusion-Weighted Imaging in Prostate Cancer

PURPOSE We evaluated the value of a combined approach of T1-weighted (T1W) imaging, T2-weighted (T2W) imaging, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) for the detection of prostate cancer and extracapsular extension (ECE) in patients with prostate cancer by using pathologic data after radical prostatectomy. MATERIALS AND METHODS Fro...

متن کامل

Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer.

OBJECTIVE The objective of our study was to compare T2-weighted MRI alone and T2 combined with diffusion-weighted imaging (DWI) for the localization of prostate cancer. SUBJECTS AND METHODS T2-weighted imaging and DWI (b value = 600 s/mm2) were performed in 49 patients before radical prostatectomy using an endorectal coil at 1.5 T in this prospective trial. The peripheral zone of the prostate...

متن کامل

Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...

متن کامل

MRI in Prostate Cancer

Imaging studies play an important role in detection and management of prostate cancer and MRI especially with the use of endorectal coil because of high contrast resolution is recognized as the best imaging modality in evaluation of prostate cancer. Multiparametric MR study including T1 and T2 weighted images, diffusion weighted images, dynamic contrast study and MR spectroscopy is useful for d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of urology

دوره 195 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2015