Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons.

نویسندگان

  • Ha Young Kim
  • Young Mog Shim
  • Kyung Soo Lee
  • Joungho Han
  • Chin A Yi
  • Yoon Kyung Kim
چکیده

PURPOSE To retrospectively compare pure pulmonary ground-glass opacity (GGO) nodules observed on thin-section computed tomography (CT) images with histopathologic findings. MATERIALS AND METHODS The institutional review board approved this study and waived informed consent. Histopathologic specimens were obtained from 53 GGO nodules in 49 patients. CT scans were assessed in terms of nodule size, shape, contour, internal characteristics, and the presence of a pleural tag. The findings obtained were compared with histopathologic results. Differences in thin-section CT findings according to histopathologic diagnoses were analyzed by using the Kruskal-Wallis test or Fisher exact test. RESULTS Of 53 nodules in 49 patients (20 men, 29 women; mean age, 54 years; range, 29-78 years), 40 (75%) proved to be broncholoalveolar cell carcinoma (BAC) (n=36) or adenocarcinoma with predominant BAC component (n=4), three (6%) atypical adenomatous hyperplasia, and 10 (19%) nonspecific fibrosis or organizing pneumonia. No significant differences in morphologic findings on thin-section CT scans were found among the three diseases (all P>0.05). A polygonal shape (25%, 10 of 40 nodules) and a lobulated or spiculated margin (45%, 18 of 40) in BAC or adenocarcinoma with predominant BAC component were caused by interstitial fibrosis or infiltrative tumor growth. A polygonal shape and a lobulated or spiculated margin were observed in two (20%) and three (30%) of 10 nodules, respectively, in organizing pneumonia/fibrosis were caused by granulation tissue aligned in a linear manner in perilobular regions with or without interlobular septal thickening. CONCLUSION About 75% of persistent pulmonary GGO nodules are attributed to BAC or adenocarcinoma with predominant BAC component, and at thin-section CT, these nodules do not manifest morphologic features that distinguish them from other GGO nodules with different histopathologic diagnoses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Focal area of ground-glass opacity and ground-glass opacity predominance on thin-section CT: discrimination between neoplastic and non-neoplastic lesions.

AIM To reveal differences in thin-section computed tomography (CT) findings between lung neoplastic lesions and non-neoplastic lesions, which showed a focal area of ground-glass opacity or ground-glass opacity predominance. MATERIALS AND METHODS A total of 82 focal areas of ground-glass opacity and ground-glass opacity predominance, consisting of 38 neoplastic and 44 non-neoplastic lesions, w...

متن کامل

Pulmonary focal fibrosis associated with microscopic arterio-venous fistula manifesting as focal ground-glass opacity on thin-section CT

BACKGROUND Focal ground-glass opacity (GGO) on thin-section computed tomography (CT) may be seen in atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ that has recently been renamed from bronchioloalveolar carcinoma (BAC) and various benign conditions. CASE PRESENTATION We report a case of pulmonary focal fibrosis associated with microscopic arterio-venous fistula (AVF), which sho...

متن کامل

Non-specific interstitial pneumonia: findings on sequential CT scans of nine patients.

BACKGROUND The purpose of this study was to describe findings on sequential high resolution computed tomographic (CT) scans of nine patients with non-specific interstitial pneumonia. METHODS Thin section CT scans of nine patients with pathologically proven non-specific interstitial pneumonia were evaluated retrospectively. All patients underwent sequential CT scanning (mean follow up 3.1 year...

متن کامل

Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT.

OBJECTIVE The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity. MATERIALS AND METHODS To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, ...

متن کامل

Thin-Section CT Findings of Arc-Welders' Pneumoconiosis

OBJECTIVE To describe the thin-section CT findings of arc-welders' pneumoconiosis. MATERIALS AND METHODS Eighty-five arc-welders with a three to 30 (mean, 15)- year history of exposure underwent thin-section CT scanning. The extent of abnormalities detected was correlated with the severity of dyspnea and pulmonary function tests. For comparison, images of 43 smoking males (mean 25 pack-year) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 245 1  شماره 

صفحات  -

تاریخ انتشار 2007