Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.
نویسندگان
چکیده
PURPOSE High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. METHODS The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. RESULTS There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28-38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. CONCLUSIONS The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.
منابع مشابه
Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملThe influence of electron multiplication and internal X-ray fluorescence on the performance of a scintillator-based gamma camera
When considering the ‘standard’ gamma-camera, one might picture an array of photo-multiplier tubes or a similar array of small-area detectors. This array of imaging detectors would be attached to a corresponding array of scintillator modules (or a solid layer of scintillator) in order to give a high detection efficiency in the energy region of interest, usually 8-140 keV. Over recent years, dev...
متن کاملCMOS X-rays detector array based on scintillating light guides
This paper describes a pixel imaging array consisting in 400 m × 400 m photodiodes fabricated in CMOS technology. An array of scintillating CsI:Tl crystals is placed above the photodiodes. These crystals are encapsulated in aluminum walls, forming a light path that guides the visible light produced by the scintillating crystal into the photodiodes. In this way, the X-ray energy is first convert...
متن کاملRecent developments in X-ray imaging with micrometer spatial resolution.
X-ray detectors for imaging with a spatial resolution in the micrometer and submicrometer range have been developed at synchrotron radiation sources since 1996. The detectors consist of a scintillator, a light microscopy optic and a charge-coupled device (CCD). The scintillator converts part of the X-ray stopped by a material into a visible-light image which is projected onto the CCD by the lig...
متن کاملDiscrete Scintillator Coupled Mercuric Iodide Photodetector Arrays for Breast Imaging
Multi-element (4x4) imaging arrays with high resolution collimators, size matched to discrete CsI(T1) scintillator arrays and mercuric iodide photodetector arrays (HgI, PDA) are under development as prototypes for larger 16x16 element arrays. The compact nature of the arrays allows detector positioning in proximity to the breast to eliminate activity not in the lineof-sight 0; the collimator, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 43 6 شماره
صفحات -
تاریخ انتشار 2016