Tale of a Wandering Lead: Late Atrial Lead Perforation into Right Lung following Pacemaker Implantation

نویسندگان

  • Arjun Saradna
  • Ankur Sinha
  • Madina Abduraimova
  • Daniel Rodriguez
  • Felix Yang
چکیده

Cardiac perforation by a pacemaker lead is a rare complication of pacemaker implantation. Presentation can vary from chest pain and shortness of breath to the patient being completely asymptomatic. Diagnosis is usually made by high-resolution computed tomography (HRCT) scan of the chest. Electrocardiograph (EKG) usually shows the absence of a paced rhythm, but it doesn't provide a definitive diagnosis. We describe a case of late cardiac perforation by an atrial pacemaker lead with no signs or symptoms of pericardial tamponade.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Life Threatening Perforation of Pacemaker Atrial Lead through the Right Atrium and the Right Lung

We report the case of a 65year old female patient who was urgently admitted to our institution with hemothorax after pacemaker implantation. The bichamber pacemaker had been implanted one week before admission and the active fixation lead caused perforation of the right atrial wall and penetration of the right lung. Transthoracic echocardiography demonstrated a minimal cardiac effusion but ches...

متن کامل

Asymptomatic Late Migration of an Atrial Pacemaker Lead into the Right Lung

This report illustrates an unusual case of asymptomatic late cardiac perforation by an atrial pacemaker lead into the right lung. In the present case, the lead was explanted by simple manual traction through the device pocket without any complications.

متن کامل

Complication of Pacemaker Implantation: An Atrial Lead Perforation

The implantation of permanent pacemakers is increasing year by year, and these devices are constantly being improved. Atrial lead perforation is an infrequent but a critical complication of pacemaker implantation. Recently, there have been increasing reports on the complication with the advances made in imaging modalities, and moreover, computed tomography scans can reveal delayed atrial lead p...

متن کامل

Long-term epicardial ventricular pacing from endocardial bipolar pacemaker lead: perforation of right atrial wall.

One of the hazards of endocardial cardiac pacing is that the pacemaker lead may perforate the myocardial wall or interventricular septum although the incidence of such perforations is believed to be small. This paper describes what is believed to be a unique case in which a pacemaker lead perforated the atrial wall at implantation (or possibly shortly afterwards) and yet gave satisfactory right...

متن کامل

Subacute right ventricular pacemaker lead perforation: evaluation by echocardiography and cardiac CT

A 77-year-old female patient with a history of chronic obstructive pulmonary disease and paroxysmal atrial fibrillation presented to our emergency department with collapse and was diagnosed with sick sinus syndrome. Before pacemaker implantation, echocardiography showed normal dimensions of both atria and ventricles and normal systolic left and right ventricle (RV) function. A DDD-R pacemaker w...