Scan quality effect on glaucoma discrimination by glaucoma imaging devices.
نویسندگان
چکیده
AIM To evaluate, within ocular imaging scans of acceptable quality as determined by manufacturers' guidelines, the effects of image quality on glaucoma discrimination capabilities. METHODS One hundred and four healthy and 75 glaucomatous eyes from the Advanced Imaging in Glaucoma Study (AIGS) were imaged with GDx-VCC, HRT II and StratusOCT. Quality score (QS>/=8), pixel standard deviation (SD/=5) were used as quality parameter cut-offs, respectively. GDx nerve fibre indicator (NFI) and HRT Moorfields regression analysis (MRA) classifications and OCT mean retinal nerve fibre layer (RNFL) thickness were used as the discriminatory parameters. Logistic regression models were used to model the dichotomous clinical classification (healthy vs glaucoma) as a function of image-quality parameters and discriminatory parameters. RESULTS Quality parameter covariates were statistically non-significant for GDx and HRT but had an inverse effect on OCT in predicting disease (a higher SS had a lower probability of glaucoma). Age was a significant covariate for GDx and HRT, but not OCT, while ethnicity and interaction between the image quality and the institute where scans were acquired were significant covariates in the OCT models. CONCLUSION Scan quality within the range recommended as acceptable by the manufacturer of each imaging device does not affect the glaucoma discriminating ability of GDx or HRT but does affect Stratus OCT glaucoma discrimination.
منابع مشابه
Compliance with Glaucoma Therapy with Eye Drops and its Determinants in Glaucoma Pa-tients Presenting to Clinics Affiliated to Shiraz University of Medical Sciences
Background: The present study was conducted to investigate medication compliance and its determinants in glaucoma patients presenting to Shahid Motahari Clinic affiliated to Shiraz University of Medical Sciences, Shiraz, Iran. The correlation between quality of life and the level of medication compliance was also evaluated in these patients. Materials and Methods: The present descriptive-analyt...
متن کاملDepression and Quality of Life in Patients with Glaucoma
Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...
متن کاملFactors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples
Spectral-domain OCT is an established tool to assist clinicians in detecting glaucoma and monitor disease progression. The widespread use of this imaging modality is due, at least in part, to continuous hardware and software advancements. However, recent evidence indicates that OCT scan artifacts are frequently encountered in clinical practice. Poor image quality invariably challenges the inter...
متن کاملLamina cribrosa visibility using optical coherence tomography: comparison of devices and effects of image enhancement techniques.
PURPOSE To compare the visibility of the lamina cribrosa (LC) in optic disc images acquired from 60 glaucoma and 60 control subjects using three optical coherence tomography (OCT) devices, with and without enhanced depth imaging (EDI) and adaptive compensation (AC). METHODS A horizontal B-scan was acquired through the center of the disc using two spectral-domain (Spectralis and Cirrus; with a...
متن کاملSpectral domain optical coherence tomography for glaucoma (an AOS thesis).
PURPOSE Optical coherence tomography (OCT) is a rapidly evolving, robust technology that has profoundly changed the practice of ophthalmology. Spectral domain OCT (SD-OCT) increases axial resolution 2- to 3-fold and scan speed 60- to 110-fold vs time domain OCT (TD-OCT). SD-OCT enables novel scanning, denser sampling, and 3-dimensional imaging. This thesis tests my hypothesis that SD-OCT improv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 93 12 شماره
صفحات -
تاریخ انتشار 2009