Small Signal Stability Analysis for a DFIG-Based Offshore Wind Farms Collected Through VSC-HVDC Transmission System

نویسندگان

  • Kai Liao
  • Zhengyou He
  • Bin Sun
  • Yong Jia
چکیده

This paper modeled a doubly fed induction generator (DFIG) based offshore wind farm integrated through a voltage source converter –based high voltage direct current (VSC-HVDC) transmission system, which is collected with infinite bus for small signal stability analysis. The control system of HVDC system is considered for the stability analysis. The impact of the VSC control parameters on the network stability is studied. The lineared dynamic model is employed to do small signal stability analysis by the eigenvalue analysis. The locus of the eigenvalue, which is corresponding to the oscillation model is studied. Time domain simulations conducted in Matlab/Simulink are used to validate the small signal stability analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of DFIG Based Offshore Wind Farms Connected Through VSC-HVDC Link on Power System Stability

With the increased levels of offshore wind power penetration into power systems, the impact of offshore wind power on stability of power systems require more investigation. In this paper, the effects of a large scale doubly fed induction generator (DFIG) based offshore wind farm (OWF) on power system stability are examined. The OWF is connected to the main onshore grid through a voltage source ...

متن کامل

Stability Analysis of Four Parallel-Operated DFIG-based Offshore Wind Farms Fed to a Large Power Grid Through a VSC-HVDC Link

This paper presents the analyzed results of using a high-voltage directcurrent (HVDC) link based on voltage-source converter (VSC) to achieve damping improvement of four parallel-operated doubly-fed induction generator (DFIG)-based offshore wind farms (OWFs) fed to a large power grid. A frequency-domain scheme based on eigenvalue analysis is carried out and a time-domain method based on nonline...

متن کامل

Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection

High-voltage dc transmission based on voltage-source converter (VSC-HVdc) is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs) to the grid in many locations. This paper presents a steady-state operation model to calculate the optimal power transmission of an OWF connected to the grid through a VSC-HVdc link. The wind tu...

متن کامل

International Journal of Smart Grid and Clean Energy Control system for offshore wind power generation system with DFIG and VSC-based HVDC transmission

This paper proposes a fundamental and efficient control technique for introducing VSC (voltage source converter)based HVDC (high voltage direct current) transmission into a large-scale offshore wind power generation system with DFIGs (doubly-fed induction generators). The electric power from the offshore wind turbine DFIG is considerably fluctuating and unstable, and needs to be transmitted fro...

متن کامل

HVDC Light for connection of wind farms

There is an increasing amount of wind farms that need to be connected to the AC transmission network. Offshore wind farms will be connected to the ac system via long submarine cables. Integration of offshore wind farms with HVDC transmission based on Voltage Source Converters (VSC), such as HVDC Light, is an advantage due to regulating properties of HVDC Light. The purpose with the Tjæreborg pr...

متن کامل