Quantitative criteria to benchmark new and existing bio-inks for cell compatibility.

نویسندگان

  • Karen Dubbin
  • Anthony Tabet
  • Sarah C Heilshorn
چکیده

Recent advancements in 3D bioprinting have led to the fabrication of more complex, more precise, and larger printed tissue constructs. As the field continues to advance, it is critical to develop quantitative benchmarks to compare different bio-inks for key cell-biomaterial interactions, including (1) cell sedimentation within the ink cartridge, (2) cell viability during extrusion, and (3) cell viability after ink curing. Here we develop three simple protocols for quantitative analysis of bio-ink performance. These methods are used to benchmark the performance of two commonly used bio-inks, poly(ethylene glycol) diacrylate (PEGDA) and gelatin methacrylate (GelMA), against three formulations of a novel bio-ink, Recombinant-protein Alginate Platform for Injectable Dual-crosslinked ink (RAPID ink). RAPID inks undergo peptide-self-assembly to form weak, shear-thinning gels in the ink cartridge and undergo electrostatic crosslinking with divalent cations during curing. In the one hour cell sedimentation assay, GelMA, the RAPID inks, and PEGDA with xanthan gum prevented appreciable cell sedimentation, while PEGDA alone or PEGDA with alginate experienced significant cell settling. To quantify cell viability during printing, 3T3 fibroblasts were printed at a constant flow rate of 75 μl min-1 and immediately tested for cell membrane integrity. Less than 10% of cells were damaged using the PEGDA and GelMA bio-inks, while less than 4% of cells were damaged using the RAPID inks. Finally, to evaluate cell viability after curing, cells were exposed to ink-specific curing conditions for five minutes and tested for membrane integrity. After exposure to light with photoinitiator at ambient conditions, over 50% of cells near the edges of printed PEGDA and GelMA droplets were damaged. In contrast, fewer than 20% of cells found near the edges of RAPID inks were damaged after a 5 min exposure to curing in a 10 mM CaCl2 solution. As new bio-inks continue to be developed, these protocols offer a convenient means to quantitatively benchmark their performance against existing inks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مکان‌یابی کتابخانه‌های عمومی منطقۀ چهار شهر تهران با استفاده از GIS

Purpose: The main objective of this study is to examine the location of public libraries in the fourth region of Tehran, based on the centrality and compatibility criteria, and to suggest more suitable locations for building new libraries. Methodology: A database of data collected in GIS environment was formed. According to predetermined criteria, the maps were prepared separately.  Based on t...

متن کامل

Retrofit of Heat Exchanger Networks Considering Existing Structure: A New Targeting Procedure

A new retrofit targeting procedure, based on pinch technology has been developed. The new procedure considers existing structure of a given network and finds the most compatible configuration with the network. To achieve this aim, the procedure uses a linear programming technique that maximize the compatibility. Good compatibility between old and new networks helps to make the best use of c...

متن کامل

A Bi-Objective Approach to an Assembly Line Re-Balancing Problem: Model and Differential Evolution Algorithms

Assembly lines are special kinds of production systems which are of great importance in the industrial production of high quantity commodities. In many practical manufacturing systems, configuration of assembly lines is fixed and designing a new line may be incurred huge amount of costs and thereby it is not desirable for practitioners. When some changes related to market demand occur, it is wo...

متن کامل

Effects of BIO on proliferation and chondrogenic differentiation of mouse marrow-derived mesenchymal stem cells

In vitro expansion of mesenchymal stem cell (MSCs) into large number is necessary for their application in cell-based treatment of articular cartilage defects. On the other hand, some studies have indicated that BIO (6-Bromoindirubin-3-Oxime) possesses mitogenic effects on cell culture. The objective of the present study was to examine the effect of BIO on in vitro expansion and chondrogenic di...

متن کامل

Assessment of the Existing Models to Estimate the Fatigue Life under both Multiaxial in Phase and 90° Out of Phase Loading Conditions

Engineers have a range of methods to estimate the fatigue life under multiaxial conditions. Each of these predictive methods is generally subjected to restrictions, related to the inherent simplified assumptions. The objective of this paper is to evaluate the validity of commonly used multiaxial fatigue criteria for different multiaxial loading conditions. The best criterion is identified throu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biofabrication

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2017