Radiation dose and image noise evaluation in coronary computed tomography angiography (CCTA) using an iterative reconstruction algorithm.
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to evaluate radiation dose reduction in coronary computerised tomography angiography (CCTA), using a commercially available iterative reconstruction (IR) algorithm as well as the behaviour of the image noise. METHODS A total cohort of 47 patients underwent CCTA examination on a 64-slice multi-detector CT. They were divided into four groups according to the time when the examination was performed (before or after the installation of iDose) and the acquisition protocol followed (prospective or retrospective electrocardiography-ECG gated). The images acquired with reduced dose settings were reconstructed using two levels (L4 and L6) of the iDose4 algorithm. Image noise was measured in all cases. RESULTS In retrospective acquisition, images acquired with a 46% lower radiation dose and reconstructed with iDose4 L6 provided noise comparable to that in the full-dose filtered back-projection images. For the prospective acquisition mode, a slight decrease (26%) in radiation dose resulted in noise improvement in low-dose images reconstructed with iDose4 L4 (16% noise removal) and L6 (30% noise removal). CONCLUSIONS The fact that image quality is improved while radiation exposure is reduced indicates that there is room for a further reduction in exposure settings. Additionally, the combination of iDose4 with prospective acquisition is able to significantly reduce the radiation dose associated with CCTA at values of about 2 mSv and even lower.
منابع مشابه
Adaptive Statistical Iterative Reconstruction-V: Impact on Image Quality in Ultralow-Dose Coronary Computed Tomography Angiography.
OBJECTIVE The clinical utility of a latest generation iterative reconstruction algorithm (adaptive statistical iterative reconstruction [ASiR-V]) has yet to be elucidated for coronary computed tomography angiography (CCTA). This study evaluates the impact of ASiR-V on signal, noise and image quality in CCTA. METHODS Sixty-five patients underwent clinically indicated CCTA on a 256-slice CT sca...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملOptimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study
AIM To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT). METHODS AND MATERIALS Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the ...
متن کاملCoronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination
AIMS To evaluate the feasibility and image quality of coronary computed tomography angiography (CCTA) acquisition with a submillisievert fraction of effective radiation dose using model-based iterative reconstruction (MBIR) for noise reduction. METHODS AND RESULTS In 42 patients undergoing standard low-dose (100-120 kV; 450-700 mA) and additional ultra-low-dose CCTA (80-100 kV; 150-210 mA) re...
متن کاملInfluence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography
BACKGROUND Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with...