The British Standards Institution 'Guide to implementing an effective respiratory protective device programme' (BS 4275) lists assigned protection factors (APFs) for various types of respiratory protective equipment (RPE). The APFs were allocated either on the basis of available workplace studies data which met set criteria or on the basis of professional judgement that there is equivalence between its operation and that of a device for which an APF is derived from workplace data. However, in many cases no workplace study information exists to support this professional judgement. As an interim measure, pending information based on workplace measurements, the breathing resistance of a range of tight-fitting RPE from negative pressure filtering devices through to self-contained positive pressure breathing apparatus was measured at various breathing rates. The relative inhalation resistances were then compared on the assumption that similar breathing resistance performance is likely to give similar inward leakage on a facepiece and hence similar protection if all other factors, such as fit, etc., are equal. This work indicates that for most devices the allocation of APFs by analogy to other devices seems to be acceptable. However, there appears to be no justification for the allocation of an APF value of 100 to continuous flow compressed air line breathing apparatus. It is recommended that it should be lowered to 40 until there is valid workplace study data to support the current APF of 100. The work provides an informative insight into the relative performance of devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of the electrospinning process of polyurethane nanofibers and their filtration performance for use in respiratory protection mask filters

Background and Aim: Electrospun nanofibers can be used to produce filter media in personal protective equipment for the military. The present study aimed to optimize the electrospinning process used to create polyurethane nanofiber substrates and compare the optimum substrate filtration performance with a typical commercial substrate used in the structure of N95 respirators. Methods: In this ex...

متن کامل

Investigating Compliance With the Standard Principles of Using Personal Protective Equipment by Nurses Exposed to Chemotherapy Drugs

Background and Aims The increasing number of patients with cancer has led to the growing use of chemotherapy drugs. This fact was followed by a growing concern about the safety and adverse effects of these drugs on healthcare staff at risks for occupational exposure to chemotherapeutic agents.  This study investigated compliance with the standard principles of using Personal Protective Equipmen...

متن کامل

The Effect of Motivational Abdominal Breathing Device on Breathing Patterns and Shortness of Breath in Patients with Chronic Obstructive Pulmonary Disease

Background and purpose: Despite the high prevalence of chronic obstructive pulmonary disease, There haven,t been definite curative treatment for the disease and focus of treatment has directed towards pulmonary rehabilitation as an effective non-drug treatments. this study were performed to determine the effect of motivational abdominal breathing device on breathing pattern and dyspnea of chron...

متن کامل

Individual Protection Adopted by ICU Nurses against Radiation and its Related Factors

Abstract Introduction: not following safety tips during mobile radiography can bring about risks for nurses in ICU wards. Objective: the study aimed to determine the status of personal protection against radiation and its associated factors in nurses working in ICU wards of health care-educational centers affiliated with Guilan University of Medical Sciences in Rasht, Iran. Materials and Met...

متن کامل

Treatment and prevention of acute respiratory infections among Iranian hajj pilgrims: a 5-year follow up study and review of the literature

  Background: Respiratory diseases/syndromes are the most common causes of referring to physicians among pilgrims in Hajj . They lead to high morbidity , impose high costs on the health system and are among the major obstacles for pilgrims to perform Hajj duties. The main aim of our study was to determine types, frequencies, etiologies, and epidemiologic factors of respiratory diseases among Ir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2002