Three-dimensional imaging of whole rodent organs using optical computed and emission tomography.

نویسندگان

  • Mark Oldham
  • Harshad Sakhalkar
  • Ying Min Wang
  • Pengyi Guo
  • Tim Oliver
  • Rex Bentley
  • Zeljko Vujaskovic
  • Mark Dewhirst
چکیده

We explore the potential of optical computed tomography (optical-CT) and optical emission computed tomography (optical-ECT) in a new area-whole organ imaging. The techniques are implemented on an in-house prototype benchtop system with improved image quality and the capacity to image larger samples (up to 3 cm) than previous systems based on stereo microscopes. Imaging performance tests confirm high geometrical accuracy, accurate relative measurement of linear attenuation coefficients, and the ability to image features at the 50-microm level. Optical labeling of organ microvasculature was achieved using two stains deposited via natural in vivo circulatory processes: a passive absorbing ink-based stain and an active fluorescin FITC-lectin conjugate. The lectin protein binds to the endothelial lining, and FITC fluorescense enables optical-ECT imaging. Three-dimensional (3-D) optical-CT images have been acquired of a normal rat heart and left lung and a mouse right lung showing exquisite detail of the functional vasculature and relative perfusion distribution. Coregistered optical-ECT images were also acquired of the mouse lung and kidney. Histological sections confirmed effective labeling of microvasculature throughout the organs. The advantages of optical-CT and optical-ECT include the potential for a unique combination of high resolution and high contrast and compatibility with a wide variety of optical probes, including gene expression labeling fluorescent reporter proteins.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Three-Dimensional Computed Tomography Diagnosis of Cranium Bifidum with Meningocele in a Lamb

Abstract   Case Description- A three-day-old male Kordi lamb had a soft painless fluctuating mass on the mid-parietal region, with no clinical signs except difficulty in standing; was referred to the clinic. Clinical Findings- Clinical examination revealed a normal body temperature, a heart rate, a respiratory rate, and inability to stand without any congenital defects Three-dimensional comp...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...

متن کامل

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 12 1  شماره 

صفحات  -