A new two-step accurate CT-MRI fusion technique for post-implant prostate cancer
نویسندگان
چکیده
PURPOSE To develop an accurate method of fusing computed tomography (CT) with magnetic resonance imaging (MRI) for post-implant dosimetry after prostate seed implant brachytherapy. MATERIAL AND METHODS Prostate cancer patients were scheduled to undergo CT and MRI after brachytherapy. We obtained the three MRI sequences on fat-suppressed T1-weighted imaging (FST1-WI), T2-weighted imaging (T2-WI), and T2*-weighted imaging (T2*-WI) in each patient. We compared the lengths and widths of 450 seed source images in the 10 study patients on CT, FST1-WI, T2-WI, and T2*-WI. After CT-MRI fusion using source positions by the least-squares method, we decided the center of each seed source and measured the distance of these centers between CT and MRI to estimate the fusion accuracy. RESULTS The measured length and width of the seeds were 6.1 ± 0.5 mm (mean ± standard deviation) and 3.2 ± 0.2 mm on CT, 5.9 ± 0.4 mm, and 2.4 ± 0.2 mm on FST1-WI, 5.5 ± 0.5 mm and 1.8 ± 0.2 mm on T2-WI, and 7.8 ± 1.0 mm and 4.1 ± 0.7 mm on T2*-WI, respectively. The measured source location shifts on CT/FST1-WI and CT/T2-WI after image fusion in the 10 study patients were 0.9 ± 0.4 mm and 1.4 ± 0.2 mm, respectively. The shift on CT/FST1-WI was less than on CT/T2-WI (p = 0.005). CONCLUSIONS For post-implant dosimetry after prostate seed implant brachytherapy, more accurate fusion of CT and T2-WI is achieved if CT and FST1-WI are fused first using the least-squares method and the center position of each source, followed by fusion of the FST1-WI and T2-WI images. This method is more accurate than direct image fusion.
منابع مشابه
The Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer
Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...
متن کاملUsing combined x-ray and MR imaging for prostate I-125 post-implant dosimetry: phantom validation and preliminary patient work.
Post-implantation dosimetry is an important element of permanent prostate brachytherapy. This process relies on accurate localization of implanted seeds relative to the surrounding organs. Localization is commonly achieved using CT images, which provide suboptimal prostate delineation. On MR images, conversely, prostate visualization is excellent but seed localization is imprecise due to distor...
متن کاملThe use of mutual information in registration of CT and MRI datasets post permanent implant.
PURPOSE To determine the feasibility of registration of MRI and CT datasets post permanent prostate implant by the use of mutual information. METHODS AND MATERIALS Five patients who underwent permanent (125)I implant for prostate carcinoma were studied. Two weeks postimplant an axial CT, T2-weighted-axial, sagittal and coronal MRI, and T1-fat-saturation MRI scans were obtained. Registrations ...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کامل[68Ga]Ga-PSMA-11 PET/CT for staging and patient management of high-risk prostate cancer: A single-center experience from Iran
Introduction: Accurate staging plays an important role in management of patients with prostate cancer especially in high-risk group. Today, [68Ga]Ga-PSMA-11 PET/CT should be considered as the preferred imaging tool for treatment planning and initial staging of the disease. Methods: A total number of 628 patients with prostate cancer referred to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2015