Simultaneous hyperpolarized (13)C-pyruvate MRI and (18)F-FDG-PET in cancer (hyperPET): feasibility of a new imaging concept using a clinical PET/MRI scanner.

نویسندگان

  • Henrik Gutte
  • Adam E Hansen
  • Sarah T Henriksen
  • Helle H Johannesen
  • Jan Ardenkjaer-Larsen
  • Alexandre Vignaud
  • Anders E Hansen
  • Betina Børresen
  • Thomas L Klausen
  • Anne-Mette N Wittekind
  • Nic Gillings
  • Annemarie T Kristensen
  • Andreas Clemmensen
  • Liselotte Højgaard
  • Andreas Kjær
چکیده

In this paper we demonstrate, for the first time, the feasibility of a new imaging concept - combined hyperpolarized (13)C-pyruvate magnetic resonance spectroscopic imaging (MRSI) and (18)F-FDG-PET imaging. This procedure was performed in a clinical PET/MRI scanner with a canine cancer patient. We have named this concept hyper PET. Intravenous injection of the hyperpolarized (13)C-pyruvate results in an increase of (13)C-lactate, (13)C-alanine and (13)C-CO2 ((13)C-HCO3) resonance peaks relative to the tissue, disease and the metabolic state probed. Accordingly, with dynamic nuclear polarization (DNP) and use of (13)C-pyruvate it is now possible to directly study the Warburg Effect through the rate of conversion of (13)C-pyruvate to (13)C-lactate. In this study, we combined it with (18)F-FDG-PET that studies uptake of glucose in the cells. A canine cancer patient with a histology verified local recurrence of a liposarcoma on the right forepaw was imaged using a combined PET/MR clinical scanner. PET was performed as a single-bed, 10 min acquisition, 107 min post injection of 310 MBq (18)F-FDG. (13)C-chemical shift imaging (CSI) was performed just after FDG-PET and 30 s post injection of 23 mL hyperpolarized (13)C-pyruvate. Peak heights of (13)C-pyruvate and (13)C-lactate were quantified using a general linear model. Anatomic (1)H-MRI included axial and coronal T1 vibe, coronal T2-tse and axial T1-tse with fat saturation following gadolinium injection. In the tumor we found clearly increased (13)C-lactate production, which also corresponded to high (18)F-FDG uptake on PET. This is in agreement with the fact that glycolysis and production of lactate are increased in tumor cells compared to normal cells. Yet, most interestingly, also in the muscle of the forepaw of the dog high (18)F-FDG uptake was observed. This was due to activity in these muscles prior to anesthesia, which was not accompanied by a similarly high (13)C-lactate production. Accordingly, this clearly demonstrates how the Warburg Effect directly can be demonstrated by hyperpolarized (13)C-pyruvate MRSI. This was not possible with (18)F-FDG-PET imaging due to inability to discriminate between causes of increased glucose uptake. We propose that this new concept of simultaneous hyperpolarized (13)C-pyruvate MRSI and PET may be highly valuable for image-based non-invasive phenotyping of tumors. This methods may be useful for treatment planning and therapy monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

BACKGROUND Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and ...

متن کامل

In Vivo Phenotyping of Tumor Metabolism in a Canine Cancer Patient with Simultaneous (18)F-FDG-PET and Hyperpolarized (13)C-Pyruvate Magnetic Resonance Spectroscopic Imaging (hyperPET): Mismatch Demonstrates that FDG may not Always Reflect the Warburg Effect.

In this communication the mismatch between simultaneous (18)F-FDG-PET and a (13)C-lactate imaging (hyperPET) in a biopsy verified squamous cell carcinoma in the right tonsil of a canine cancer patient is shown. The results demonstrate that (18)F-FDG-PET may not always reflect the Warburg effect in all tumors.

متن کامل

Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...

متن کامل

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

FDG-PET/MRI fused data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment

Background: To retrospectively describe imaging characteristics of liver metastases on fused FDG-PET/ MRI data sets and to compare the diagnostic accuracy of MRI and fused FDG-PET/MRI data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment. Materials and Methods: 43 oncological patients (mean age: 56+/- 11 years) were investigated by FDG-PET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of nuclear medicine and molecular imaging

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2015