Radioactivity in HgCdTe devices: potential source of “snowballs”

نویسنده

  • P. McCullough
چکیده

We hypothesize that the “snowballs” observed in HgCdTe infrared detectors are caused by natural radioactivity in the devices themselves. As characterized by Hilbert (2009) in the WFC3 flight IR array (FPA165), “snowballs” are transient events that instantaneously saturate a few pixels and deposit a few hundred thousand electrons over a ~5-pixel (~100-um) diameter region. In 2008, prior to flight of detector FPA165, Hilbert (2009) detected 21 snowballs during thermal vaccum test three (TV3) and inferred a rate of ~1100 ± 200 snowballs per year per cm of the HgCdTe detector. Alpha particles emitted from either (or both) naturally radioactive thorium and/or uranium, at ~1 ppm concentrations within the device, can explain the observed characteristics of the “snowballs.” If thorium is present, up to four distinctly observable snowballs should appear at the same location on the pixel array over the course of many years. While the indium in the bump bonds is almost entirely the radioactive isotope In-115, and 12% of the cadmium is naturally radioactive Cd-113, both of those emit only betas, which are too penetrating and not energetic enough to match the observed characteristics of “snowballs.” Also, the Cd-113 emission rate is much less than that of the observed

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THz Photoresponse and Magnetotransport of detectors made of HgCdTe/HgTe quantum well structures

In addition to spaceand time-resolved measurements of the electrical generation of excited electrons in quantum Hall (QH) devices the dissipation in these devices induced by Terahertz (THz) laser impulses is investigated. For these tasks a THz laser system ( p-Ge-Laser [1]) is applied. This laser uses transitions between Landau levels of light holes and emits laser impulses with an adjustable d...

متن کامل

کنترل کیفی و کالیبراسیون دستگاه های دزکالیبراتور RAMS-88 در مراکز پزشکی هسته ای ایران

  The aim of this paper is the examining ways for quality control and calibration of Rams-88 calibrator. The device measures the amount of &gamma and &beta rays in radio medicines by means of the amount of radioactivity of radio nuclide. In this paper experiments has been done for explaining correct operation of these devices using standard method including precision, accuracy and linearit...

متن کامل

2048x2048 VISIBLE/INFRARED HgCdTe FOCAL PLANE ARRAYS (FPAs)

Rockwell has developed the world’s largest multiplexer for use with infrared HgCdTe and visible silicon detector arrays. The resulting FPAs are to be proposed for the Next Generation Space Telescope (NGST) program, ground-based astronomy, and other low background applications. The 2048x2048 multiplexer’s unit cell size is 18 μm x 18 μm with source follower per detector input (SFD) and 4 and 32 ...

متن کامل

Quantum-dot infrared photodetectors: Status and outlook

This paper reviews the present status and possible future developments of quantum-dot infrared photodetectors (QDIPs). At the beginning the paper summarizes the fundamental properties of QDIPs. Next, an emphasis is put on their potential developments. Investigations of the performance of QDIPs as compared to other types of infrared photodetectors are presented. A model is based on fundamental p...

متن کامل

Snowballs Are Quasiballs

We introduce snowballs, which are compact sets in R3 homeomorphic to the unit ball. They are 3-dimensional analogs of domains in the plane bounded by snowflake curves. For each snowball B a quasiconformal map f : R3 → R3 is constructed that maps B to the unit ball.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009