What monitor can replace the cathode-ray tube for visual stimulation to elicit multifocal electroretinograms?

نویسندگان

  • Celso Soiti Matsumoto
  • Kei Shinoda
  • Harue Matsumoto
  • Keisuke Seki
  • Eiichiro Nagasaka
  • Takeshi Iwata
  • Atsushi Mizota
چکیده

To compare a conventional cathode-ray tube (CRT) screen to organic light-emitting diode (OLED) and liquid crystal display (LCD) screens as visual stimulators to elicit multifocal electroretinograms (mfERGs), mfERGs were recorded from seven eyes of seven healthy volunteers (21 ± 2 years). The mfERGs elicited by a conventional CRT screen (S710, Compaq Computer Co.) were compared to those elicited by a studio-grade master OLED monitor (PVM-1741, Sony, Japan) and a conventional LCD (S1721, Flexscan, Eizo Nanao Corp., Japan). The luminance changes of each monitor were measured with a photodiode. CRT, OLED, and LCD screens with a frame frequency of 60 Hz were studied. A hexagonal stimulus array with 61 stimulus elements was created on each monitor. The serial white stimuli of the OLED screen at 60 Hz did not fuse, and that of the LCD screens fused. The amplitudes of P1 and P2 of the first-order kernels of the mfERGs were not significantly different from those elicited by the CRT and OLED screens, and the P1 amplitude of the first-order kernel elicited by the LCD stimuli was significantly smaller than that elicited by the CRT in all the groups of the averaged hexagonal elements. The implicit times were approximately 10 ms longer in almost all components elicited by the LCD screen compared to those elicited by the CRT screen. The mfERGs elicited by monitors other than the CRT should be carefully interpreted, especially those elicited by LCD screens. The OLED had good performance, and we conclude that it can replace the CRT as a stimulator for mfERGs; however, a collection of normative data is recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pattern Visual Evoked Potentials Elicited by Organic Electroluminescence Screen

PURPOSE To determine whether organic electroluminescence (OLED) screens can be used as visual stimulators to elicit pattern-reversal visual evoked potentials (p-VEPs). METHOD Checkerboard patterns were generated on a conventional cathode-ray tube (S710, Compaq Computer Co., USA) screen and on an OLED (17 inches, 320 × 230 mm, PVM-1741, Sony, Tokyo, Japan) screen. The time course of the lumina...

متن کامل

Effects of stimulus blocking, light scattering, and distortion on multifocal electroretinogram.

PURPOSE To investigate how the multifocal electroretinogram (ERG) is altered in conditions of blocking, light scattering, or distortion of the stimulus that are seen in ocular pathologies. METHODS A central 40 degree-diameter stimulus pattern consisting of 61 hexagons was presented on a cathode ray tube monitor at a rate of 75 Hz according to the pseudo-random binary M sequence by the Veris c...

متن کامل

Evaluation of an organic light-emitting diode display for precise visual stimulation.

A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatia...

متن کامل

Study for Analysis of the Multifocal Visual Evoked Potential

PURPOSE To introduce the clinical utility of the absolute value of the reconstructed waveform method in the analysis of multifocal visual evoked potential (mfVEP). METHODS The mfVEP with 4-channel recording was performed using RETIscan® on 10 eyes of 10 normal subjects. Amplitudes were obtained from ring-shaped 6 areas and 4 sectors. The best visual evoked potential (VEP) response method and ...

متن کامل

Visual Evoked Potential Using Head-Mounted Display Versus Cathode Ray Tube: A Pilot Study

OBJECTIVE To present a new stimulation method based on the use of a head-mounted display (HMD) during pattern reversal visual evoked potential (PR-VEP) testing and to compare variables of HMD to those of conventional cathode ray tube (CRT). METHODS Twenty-three normal subjects without visual problems were recruited. PR-VEPs were generated using CRT or HMD stimuli. VEP outcome measures include...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vision

دوره 14 9  شماره 

صفحات  -

تاریخ انتشار 2014