BACKGROUND The recommended approach to screening for primary aldosteronism (PA) in at-risk populations is to determine the ratio of aldosterone concentration (serum (SAC)/plasma (PAC)) to renin measured in plasma as activity (PRA) or concentration (DRC). However, lack of assay standardisation mandates the need for method-specific decision thresholds and clinical validation in the local population. AIM The study objective was to establish method-specific aldosterone: renin ratio (ARR) cut-offs for PA in men and women using the IDS-iSYS® assay system (IDS plc). METHODS A prospective cohort study design was used. PAC and DRC were measured immunochemically in ethylenediamine-tetraacetic acid (EDTA) plasma on the IDS-iSYS® instrument. RESULTS A total of 437 subjects (218 men, 219 women) were recruited including: healthy normotensive volunteers (n=266) and women taking the oral contraceptive pill (OCP; n=15); patients with essential hypertension (EH; n=128); confirmed PA (n=16); adrenal cortical carcinoma (ACC; n=3); Addison's disease (AD; n=4) and phaeochromocytoma/paraganglioma (PPGL; n=5). In this population, an ARR cut-off at >37.4 pmol/mIU provided 100% diagnostic sensitivity, 96% specificity and positive likelihood ratio for PA of 23:1. When the ARR decision threshold was stratified according to gender, a cut-off of >26.1 pmol/mIU in men and >113.6 pmol/mIU in women resulted in diagnostic sensitivity and specificity of 100%. CONCLUSION This study demonstrates that decision thresholds for PA should not only be method-specific but also gender-specific. However, given the small number of PA patients (n=16), particularly women (n=4), further validation through a prospective study with a larger PA cohort is required before the thresholds presented here could be recommended for routine clinical use.
منابع مشابه
IDS iSYS automated intact procollagen-1-N-terminus pro-peptide assay: method evaluation and reference intervals in adults and children.
BACKGROUND We carried out a technical evaluation of the Immunodiagnostic Systems (IDS) automated intact procollagen-I N-terminus propeptide (PINP) assay on the iSYS platform, and established reference intervals for PINP in both adults and children. METHODS Assay imprecision, recovery and interference were studied. Serum and plasma values were compared, and PINP stability was assessed. Using 8...
متن کاملFour automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.
BACKGROUND Comparing four fully automated 25-OH-D immunoassays to a commercially available liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with human serum samples from Finnish population. METHODS 400 samples were analyzed with the Liaison Total Vitamin D, the IDS-iSYS 25-Hydroxy Vitamin D, the ARCHITECT 25-OH Vitamin D, the ADVIA Centaur Vitamin D Total, and a commercially a...
متن کاملMethod evaluation study of a new generation of vitamin D assays
INTRODUCTION Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme li...
متن کاملReference intervals for serum osteocalcin concentrations in adult men and women from the study of health in Pomerania
BACKGROUND Osteocalcin (OC) is a bone-specific protein produced primarily by osteoblasts during bone formation. Besides its role in bone formation, osteocalcin may play a role in the regulation of energy metabolism and male fertility. To interpret serum OC data, reference intervals adapted to a specific laboratory method are needed. METHODS A healthy reference population was selected from the...
متن کاملQuantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening
In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...