Whole-Brain FLAIR using 3D TSE with Variable Flip Angle Readouts Optimized for 7 Tesla
نویسندگان
چکیده
Introduction Whole-brain FLAIR is a requirement for most routine clinical neuroimaging. Traditional techniques employ a two-dimensional inversion-recovery turbo spin echo (2D IR-TSE) pulse sequence with the inversion time (TI) chosen to null CSF signal. However, at 7 Tesla (T) and higher whole-brain FLAIR using traditional techniques has not been feasible in an acceptable scan time. The traditional FLAIR pulse sequence requires a large number of inversion and refocusing pulses which leads to a prohibitively high SAR and only a few slices can be acquired at ultra-high B0 [1]. Furthermore, B1 inhomogeneity at 7T makes robust CSF suppression very difficult to achieve with 2D techniques. Recent work [2] demonstrated the feasibility of using 3D IR-TSE with a T2-selective inversion pulse and a long echo train with a reduced flip angle readout (70o) to perform whole brain FLAIR at 7 Tesla for the first time. The present work seeks to extend this approach by adding a variable flip angle readout, optimized for the T1 and T2 values of brain tissues at 7T, to further reduce SAR and improve contrast and SNR per unit time. Methods Bloch simulations were performed to explore the optimal combinations of TI, TR, echo train length (ETL), and flip angle evolution to achieve robust CSF suppression, and to maintain excellent contrast between gray matter (GM) and white matter (WM) regions using typical GM H2O relaxation properties [3]. Data were acquired at 7T (MAGNETOM 7T, Siemens) using either an 8-channel phased array head coil (Rapid Biomedical) or a 24channel phased array head coil (Nova Medical). A T2-selective adiabatic IR pulse was used to selectively invert CSF H2O signal. Combinations of TI and TR were tested to confirm optimal values for CSF suppression and to compare with simulations. The T1 and T2 values used in the Bloch simulations to optimize the variable flip angle RF pulse train were matched to typical values of gray matter at 7 T [3], using a variable flip angle train designed to yield improved SNR for long echo trains. The TE was varied to determine the best combination of T2 contrast and minimal blurring along the phase encoding axes. Both a sagittal whole-brain 160 slice (1mm) voxel protocol and a lower spatial resolution axial whole-brain 96 slice (1mm)x2mm voxel protocol were developed. Elliptical sampling of kspace along the phase encode axes was also added to reduce scan time. After initial testing in phantoms to confirm that the pulse sequence could operate reliably within SAR constraints for a reasonable scan time, optimization was performed with eleven subjects scanned under informed consent, including one subject with small confirmed WM lesions. Images were evaluated on the basis of low SAR, practical scan time, uniformly good CSF suppression, contrast between cortical GM and WM, and image sharpness. Image sharpness was evaluated visually along all three dimensions using multi-planar reformatting of the 3D image volume. Results and Discussion GM and WM H2O T1 values increase significantly with B0, while CSF H2O T1 does not [3]. Thus, the TI required to null CSF signal is independent of B0, and the recovery from inversion of WM/GM signals at 7T is substantially reduced compared to acquisitions at lower B0. The use of a T2-selective inversion pulse significantly increases the GM/WM signal recovery compared to a regular inversion pulse. Fig. 1 shows the variable flip angle evolution scheme optimized for 7T brain tissue relaxation times for the high resolution sagittal protocol. The bend in the middle of the flip angle evolution corresponds to the center of k-space and the TE. After a rapid fall off from 180° at the beginning of the RF pulse train, the lower flip angles in the first half of the train will significantly prolong the decay and thus reduce blurring due to higher T1 components. The flip angle at the center of the pulse train is approximately 20° representing a major reduction in RF energy compared to 180° refocusing pulses used in typical 2D TSE FLAIR, and also compared to the previously reported 70° 3D TSE readout [2]. Optimal CSF suppression was achieved with TI/TR=2350/10000ms, yielding excellent suppression over the entire brain in all subjects. A high BW=751Hz/pixel was used to reduce the echo spacing to 3.4ms which shortened the echo-train length and minimized blurring. A long TE (380ms) had a minimal affect on SNR for the flip angle train shown in Fig 1, and the long TE improved both the GM/WM contrast and reduced through-slice blurring. Elliptical k-space sampling shortened the scan time by 15-20% depending on the amount of partial Fourier acceleration used. The optimized axial protocol with (1mm)x2mm resolution had a scan time of 6m11sec. The CSF suppression and GM/WM contrast were very good throughout the brain, and the resolution was higher than typical clinical FLAIR protocols. A comparable 2D FLAIR protocol could only acquire approximately 5 slices within the same scan time due to SAR constraints at 7 Tesla. The optimized sagittal protocol with (1mm) resolution had a scan time of 10m14sec. Multi-planar reformatted images acquired using this protocol are shown in Fig. 2 for a subject with confirmed WM lesions highlighted in red. In conclusion, 3T TSE with a variable flip angle readout optimized for 7 Tesla brain and a long echo train combined with T2-selective IR and elliptical imaging provides excellent quality whole-brain FLAIR images at 7 T in a practical scan time. References [1] Zwanenburg Eur. Rad. Oct. 3 (2009). [2] Visser, Proc. ISMRM 2009 (#2760). [3] Rooney, MRM 57:308-318 (2007).
منابع مشابه
Development of a clinically practical whole-brain intracranial vessel wall MRI technique at 3 Tesla
Background T1-weighted variable-flip-angle 3D TSE has emerged as a promising intracranial vessel wall imaging technique. To increase spatial coverage and cerebrospinal fluid (CSF) attenuation, a whole-brain 0.5-mm-reoslution protocol based on an inversion-prepared 3D TSE sequence has recently been proposed at 3T. However, its 11-12-min scan time renders it clinically impractical. This work aime...
متن کامل"Spin-echo Like T1 Contrast" Volumetric Black-Blood Images Using 3D LOWRAT: Low Refocusing Flip Angle TSE
Introduction: T1 contrast is typically acquired using multi-slice two-dimensional spin-echo (2D SE), inversion recovery fast spin echo (T1 fluid-attenuated inversion recovery : T1FLAIR) or 3D T1-weighted spoiled gradient-echo (3D T1TFE) imaging [1]. However, these conventional methods have problems when used for contrast enhancement studies. 2D-SE requires long scan time for 3-plane diagnosis, ...
متن کاملDual Contrast 3D-TSE, T2w and FLAIR imaging at 7.0 Tesla
Introduction: Multi slice T2w-TSE and FLAIR-TSE sequences are two of the most important techniques in neuro-radiology. The problem of partial volume effects and inherent CSF-inflow artifacts in FLAIR can be resolved by using a non-selective 3D-TSE acquisition technique with advanced refocusing pulse angle sweep [1]. A disadvantage of 3D TSE sequences with isotropic voxel size smaller than 1mm i...
متن کاملUltra-High Field Optimization of the Double Inversion Recovery (DIR) sequence: Gray Matter Imaging at 7T
Target Audience: Clinicians and scientists who perform gray matter imaging and lesion detection with the DIR sequence. Purpose: The goal of this project was to develop an optimized double inversion recovery (DIR) sequence [1] for gray matter imaging at ultra-high field (7 Tesla). Several issues compromise image quality and scanning efficiency when the DIR sequence is used at ultra-high field: S...
متن کاملIncreased sensitivity to low concentration gadolinium contrast by optimized heavily T2-weighted 3D-FLAIR to visualize endolymphatic space.
PURPOSE To increase the sensitivity of 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) to low concentration gadolinium (Gd)-based contrast medium, we optimized sequence parameters on a phantom and evaluated the optimized sequence in patients suspicious for endolymphatic hydrops. MATERIALS AND METHODS All scans were performed on a 3-tesla magnetic resonance (MR) unit using a 32-ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009