Use of neural response telemetry measures to objectively set the comfort levels in the Nucleus 24 cochlear implant.

نویسندگان

  • John E King
  • Marek Polak
  • Annelle V Hodges
  • Stacy Payne
  • Fred F Telischi
چکیده

Cochlear implant programming necessitates accurate setting of programming levels, including maximum stimulation levels, of all active electrodes. Frequently, clinical techniques are adequate for setting these levels; however, they are sometimes insufficient (e.g., very young children). In the Nucleus 24, several methods have been suggested for estimation of comfort levels (C levels) from neural response telemetry (NRT); however, many require co-application of clinical measurements. Data was obtained from 21 adult Nucleus 24 recipients to develop reliable predictions of C levels. Multiple regression analysis was performed on NRT threshold, slope of the NRT growth function, age, length of deafness, length of cochlear implant use and electrode impedance to examine predictive ability. Only the NRT threshold and slope of the growth function measures were significant predictors yielding R2 values from 0.391 to 0.769. Results demonstrated that these measures may provide an alternative means of estimating C levels when other clinical measures are unavailable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perimodiolar electrode position: Effects on thresholds, comfort levels, impedance measurements, and neural response telemetry

OBJECTIVE: This multicenter study describes the effects of perimodiolar electrode position on 50 adult patients (31 with an implanted Nucleus 24 Contour perimodiolar hugging electrode array [Cochlear Limited, Lane Cove, NSW, Australia] and 19 with an implanted straight electrode array) with a severe-to-profound sensorineural hearing loss. MATERIALS AND METHODS: In all patients, intraoperative i...

متن کامل

Outcomes of cochlear implantation in children with auditory neuropathy.

Ten children who were diagnosed with auditory neuropathy were matched with ten children who were diagnosed with other etiologies. All twenty children received cochlear implants at the Mayo Clinic in Rochester, Minnesota. Various measures were used to compare the outcomes for the two groups. We compared the children's unaided and aided audiograms, and measures of threshold and comfort levels. Pe...

متن کامل

Neural response telemetry measures in patients implanted with Nucleus 24.

UNLABELLED Cochlear implantation has been recommended for children under 24 months of age. The use of objective measures is needed to help speech processor programming. The electrically evoked compound potential (EAP), which can be assessed by neural response telemetry (NRT), is one of those objective measures. AIM to determine how often the EAP can be recorded by NRT system during surgery an...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

Relationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery

Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them.   Materials and Methods: Ten children with a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2006