A novel fluoroscopy-free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock.

نویسندگان

  • Daniel J Scott
  • Jonathan L Eliason
  • Carole Villamaria
  • Jonathan J Morrison
  • Robert Houston
  • Jerry R Spencer
  • Todd E Rasmussen
چکیده

BACKGROUND Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a potentially lifesaving maneuver in the setting of hemorrhagic shock. However, emergent use of REBOA is limited by existing technology, which requires large sheath arterial access and fluoroscopy-guided balloon positioning. The objectives of this study were to describe a new, fluoroscopy-free REBOA system and to compare its efficacy to existing technology. An additional objective was to characterize the survivability of 60 minutes of REBOA using these systems in a model of hemorrhagic shock. METHODS Swine (70-88 kg) in shock underwent 60 minutes of REBOA using either a self-centering, one component prototype balloon system (PBS, n = 8) inserted (8 Fr) and inflated without fluoroscopy or a two-component, commercially available balloon system (CBS, n = 8) inserted (14 Fr) with fluoroscopic guidance. Following REBOA, resuscitation occurred for 48 hours with blood, crystalloid, and vasopressors. End points included accurate balloon positioning, hemodynamics, markers of ischemia, resuscitation requirements, and mortality. RESULTS Posthemorrhage mean arterial pressure (mm Hg) was similar in the CBS and PBS groups (35 [8] vs. 34 [5]; p = 0.89). Accurate balloon positioning and inflation occurred in 100% of the CBS and 88% of the PBS group. Following REBOA, mean arterial pressure increased comparably in the CBS and PBS groups (81 [20] vs. 89 [16]; p = 0.21). Lactate peaked in the CBS and PBS groups (10.8 [1.4] mmol/L vs. 13.2 [2.1] mmol/L; p = 0.01) 45 minutes following balloon deflation but returned to baseline by 24 hours. Mortality was similar between the CBS and PBS groups (12% vs. 25%, p = 0.50). CONCLUSION This study reports the feasibility and efficacy of a novel, fluoroscopy-free REBOA system in a model of shock. Despite a significant physiologic insult, 60 minutes of REBOA is tolerated and recoverable. Development of lower profile, fluoroscopy-free endovascular balloon occlusion catheters may allow proactive aortic control in patients at risk for hemorrhagic shock and cardiovascular collapse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopy-free Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for controlling life threatening postpartum hemorrhage

BACKGROUND Severe postpartum hemorrhage occurs in 1/1000 women giving birth. This condition is often dramatic and may be life threatening. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) has in recent years been introduced as a novel treatment for hemorrhagic shock. We present a series of fluoroscopy-free REBOA for controlling life threatening postpartum hemorrhage. METHODS ...

متن کامل

Resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct for hemorrhagic shock.

Temporary occlusion of the aorta as an operative method to increase proximal or central perfusion to the heart and brain in the setting of shock is not new.1 Resuscitative aortic occlusion with a balloon was reported as early as the Korean War and has been described in more recent publications.2–5 Despite potential advantages over thoracotomy with aortic clamping, resuscitative endovascular bal...

متن کامل

Endovascular balloon occlusion of the aorta is superior to resuscitative thoracotomy with aortic clamping in a porcine model of hemorrhagic shock.

BACKGROUND Noncompressible torso hemorrhage is the leading cause of potentially preventable death on the modern battlefield. The objective of this study is to characterize resuscitative aortic balloon occlusion (BO) compared to thoracotomy with aortic clamping in a model of hemorrhagic shock. METHODS A total of 18 swine (3 groups; 6 animals/group) were used in this study. Swine in class IV sh...

متن کامل

A clinical series of resuscitative endovascular balloon occlusion of the aorta for hemorrhage control and resuscitation.

BACKGROUND A requirement for improved methods of hemorrhage control and resuscitation along with the translation of endovascular specialty skills has resulted in reappraisal of resuscitative endovascular balloon occlusion of the aorta (REBOA) for end-stage shock. The objective of this report was to describe implementation of REBOA in civilian trauma centers. METHODS Descriptive case series of...

متن کامل

Endovascular resuscitation techniques for severe hemorrhagic shock and traumatic arrest in the presurgical setting.

Novel aortic catheter-based resuscitation interventions aimed at control of noncompressible torso hemorrhage and resuscitative perfusion are undergoing active research and development. These methods have been reported as resuscitative endovascular balloon occlusion of the aorta, selective aortic arch perfusion, and profound hypothermia (emergency preservation and resuscitation). These intervent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of trauma and acute care surgery

دوره 75 1  شماره 

صفحات  -

تاریخ انتشار 2013