Motion artifact reduction on parametric PET images of neuroreceptor binding.

نویسندگان

  • Hans Herzog
  • Lutz Tellmann
  • Roger Fulton
  • Isabelle Stangier
  • Elena Rota Kops
  • Kay Bente
  • Christian Boy
  • Rene Hurlemann
  • Uwe Pietrzyk
چکیده

UNLABELLED PET studies of cerebral neuroreceptors are often recorded over periods ranging from 1 to 2 h, and head movements during the studies not only lead to blurred images but also may seriously disturb the kinetic analysis. We report the effect of motion on parametric images of the distribution volume ratio (DVR), as well as possible improvements if the dynamic PET data are corrected for head movements. METHODS The study was performed with the 5-hydroxytryptamine 2A receptor ligand (18)F-altanserin. During PET scanning, which was performed in list mode for 1 h, the position of the head was monitored by an infrared motion-tracking system. The list mode data were sorted into time frames of between 10 s and 2 min. Motion was corrected using the multiple-acquisition-frame (MAF) approach, which calculates individual attenuation files for each emission frame and its corresponding head position to avoid misalignment of transmission and emission data. After reconstruction of attenuation-corrected emission frames, each image frame was realigned to match the head position of the first frame of the emission scan. The resulting motion-corrected dynamic images were evaluated using the noninvasive Logan plot to obtain parametric images of DVR. RESULTS DVR images of motion-affected (18)F-altanserin scans showed artifacts whose extent depended on the amount of movement. The artifacts were mainly at the border between gray matter and white matter and at the outer border of gray matter. They were seen as discontinuities and small spots whose values exceeded the expected DVR values or were even negative and that disappeared when motion correction was applied. These effects in human data were also seen on simulated (18)F-altanserin images that contained no statistical noise. CONCLUSION Whereas the native PET images looked just blurred if the patient moved during the PET scan, parametric images of the Logan DVR, which are calculated by pixelwise linear regression, contained severe discontinuities primarily at the cortical edge. MAF-based motion correction was able to avoid these errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET kinetic analysis: wavelet denoising of dynamic PET data with application to parametric imaging.

Physiological functions (e.g., cerebral blood flow, glucose metabolism, and neuroreceptor binding) can be investigated as parameters estimated by kinetic modeling using dynamic positron emission tomography (PET) images. Imaging of these physiological parameters, called parametric imaging, can locate the regional distribution of functionalities. However, the most serious technical issue affectin...

متن کامل

Omission of serial arterial blood sampling in neuroreceptor imaging with independent component analysis.

We have previously proposed a statistical method for extracting a plasma time-activity curve (pTAC) from dynamic PET images, named EPICA, for kinetic analysis of cerebral glucose metabolism. We assumed that the dynamic PET images consist of a blood-related component and a tissue-related component which are spatially independent in a statistical sense. The aim of this study is to investigate the...

متن کامل

Development, Validation and Application of Advanced Neuroimaging Analysis Tools for in Vivo Neuroreceptor Studies

Positron emission tomography (PET) is an imaging technology, which can be used to study neuroreceptors in the human brain in vivo. The technique estimates the regional binding of radiolabelled ligands to neuroreceptors and the data are commonly displayed as images showing the distribution of radioactivity in the brain volume. A traditional image analysis approach builds upon reduction of noise ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Positron Emission Tomography Compartmental Models: A Basis Pursuit Strategy for Kinetic Modelling

A kinetic modelling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET) is presented. The approach is based on a general compartmental description of the tracer’s fate in vivo and determines a parsimonious model consistent with the measured data. The technique involves the determination of a sparse selection of kinetic basis functions from a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2005